3.
Select Enclosure Indicators.
4.
Select the enclosure of choice and click Continue.
5.
Make the necessary changes to the selection list located next to each location code.
6.
To save the changes made to the state of one or more FRU indicators, click Save settings.
To turn off all of the indicators for this enclosure, click Turn off all. A report page is displayed
indicating success or failure.
Removing and replacing covers on the 8231-E2B, 8231-E1C, 8231-E1D,
8231-E2C, 8231-E2D, or 8268-E1D system
Use these instructions to remove, replace, or install covers to access components or perform service.
Removing the service access cover from the 8231-E2B, 8231-E1C,
8231-E1D, 8231-E2C, 8231-E2D, or 8268-E1D
Use this procedure to remove the service access cover.
Perform the following steps to remove the service access cover:
1.
Loosen the thumbscrew (A) located at the rear of the cover.
2.
Slide the cover (B) toward the rear of the system. When the front of the service access cover has
cleared the upper frame ledge, lift the cover up and off the system.
Attention:
When the service access cover is removed, the system powers down.
Figure 28. Removing the service access cover
46