Chapter 7. Solving problems
119
00019703
Processor 3 failed the built-in self test.
Action:
Replace microprocessor 3.
(The Microprocessor 3 Error LED will be on.)
If the problem persists, call for service.
00019704
Processor 4 failed the built-in self test.
Action:
Replace microprocessor 4.
(The Microprocessor 4 Error LED will be on.)
If the problem persists, call for service.
00180100
A PCI adapter has requested memory resources that are not available.
Action:
1. Make sure that the PCI adapter and all other adapters are set correctly in the
Configuration/Setup Utility program. If the memory resource settings are not
correct, change the settings.
2. If all memory resources are being used, you might need to remove an adapter to
make memory available to the PCI adapter. Disabling the adapter BIOS on the
adapter might correct the error. Refer to the documentation provided with the
adapter.
00180200
A PCI adapter has requested an I/O address that is not available, or the PCI adapter might be
defective.
Action:
1. Make sure that the I/O address for the PCI adapter and all other adapters are set
correctly in the Configuration/Setup Utility program.
2. If the I/O port resource settings are correct, the PCI adapter might be defective.
Call for service.
00180300
A PCI adapter has requested a memory address that is not available, or the PCI adapter might be
defective.
Action:
1. Make sure that the memory address for all other adapters are set correctly in the
Configuration/Setup Utility program. If the memory resource settings are not
correct, change the settings.
2. If the memory resource settings are correct, the PCI adapter might be defective.
Call for service.
00180400
A PCI adapter has requested a memory address that is not available.
Action:
If all memory addresses are being used, you might need to remove an adapter to
make memory address space available to the PCI adapter. Disabling the adapter
BIOS on the adapter might correct the error. Refer to the documentation provided with
the adapter.
00180500
A PCI adapter ROM error occurred.
Action:
Remove the PCI adapters. If you can start the server without the adapters, reinstall
each adapter one at a time and retest after each is reinstalled. When an adapter fails,
replace it.
If you cannot isolate and correct the problem, call for service.
00180600
A PCI-to-PCI bridge error occurred. More than one PCI bus tried to access memory below 1 MB.
Action:
Remove the PCI adapter that has the PCI bridge. If you can start the server without
the adapter, reinstall and retest the adapter. If the adapter fails, replace it.
If you cannot isolate and correct the problem, call for service.
POST message
Description
Table 16. POST error messages
Summary of Contents for Netfinity 7100
Page 1: ...IBM IBM Netfinity 7100 User s Reference SC19 K081 10 ...
Page 2: ......
Page 3: ...IBM IBM Netfinity 7100 User s Reference SC19 K081 10 ...
Page 7: ...Contents v Index 183 ...
Page 8: ...vi IBM Netfinity 7100 User s Reference ...
Page 34: ...20 IBM Netfinity 7100 User s Reference ...
Page 72: ...58 IBM Netfinity 7100 User s Reference ...
Page 174: ...160 IBM Netfinity 7100 User s Reference ...
Page 196: ...182 IBM Netfinity 7100 User s Reference ...
Page 199: ......