IBM® Netfinity® 7100 User’s Reference
POST error messages
The following tables provide information about the POST error messages that can
appear during startup.
POST message
Description
062
The server failed to boot on three consecutive attempts.
All caches are disabled. Repeatedly turning the server on and then off or resetting the server
might cause this problem.
Action:
Start the Configuration/Setup Utility program and verify that all settings are correct.
Use the Cache Control selection in the Advanced Setup menu of the
Configuration/Setup Utility program to enable the caches.
If the problem persists, call for service. When the problem is corrected, be sure to enable the
caches.
101
102
106
An error occurred during the system board and microprocessor test.
Action:
Call for service.
114
An adapter read-only memory (ROM) error occurred.
Action:
Remove the options. If you can start the server without the options installed, reinstall
each option one at a time and retest after each is reinstalled. When an option fails,
replace it.
If you cannot isolate and correct the problem, call for service.
129
An error was detected in the L1 cache of one of the microprocessors.
Action:
1. If you just installed a microprocessor, verify that the microprocessor is installed
and seated correctly.
2. If the problem persists, check to see if the system has isolated the problem to a
microprocessor:
• If the System Error light on the operator information panel is on, check to see
if the CPU LED on the diagnostic LED panel is on. If it is on, check the
Microprocessor Error LEDs next to the microprocessor sockets.
— If a Microprocessor LED is on, run the diagnostic program for the
microprocessor indicated by the LED. If the tests fail, replace the
indicated microprocessor.
— If the microprocessor tests do not fail, call for service.
• If no error LED is on, the error logs in the Configuration/Setup Utility program
might provide additional information about the microprocessor error.
If the problem persists, call for service.
151
A real-time clock (RTC) error occurred.
Action:
Call for service.
161
The real-time clock battery has failed.
Action:
Replace the battery yourself or call for service.
You can use the server until you replace the battery. However, you must run the
Configuration/Setup Utility program and set the time and date and other custom settings each
time you turn on the server.
Table 16. POST error messages
Summary of Contents for Netfinity 7100
Page 1: ...IBM IBM Netfinity 7100 User s Reference SC19 K081 10 ...
Page 2: ......
Page 3: ...IBM IBM Netfinity 7100 User s Reference SC19 K081 10 ...
Page 7: ...Contents v Index 183 ...
Page 8: ...vi IBM Netfinity 7100 User s Reference ...
Page 34: ...20 IBM Netfinity 7100 User s Reference ...
Page 72: ...58 IBM Netfinity 7100 User s Reference ...
Page 174: ...160 IBM Netfinity 7100 User s Reference ...
Page 196: ...182 IBM Netfinity 7100 User s Reference ...
Page 199: ......