Optional-device problems
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 8850,” on page 53 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Symptom
Action
An IBM optional device that was
just installed does not work.
1. Make sure that:
v
The option is designed for the server (see the ServerProven
®
list on the
World Wide Web at http://www.ibm.com/us/compat/).
v
You followed the installation instructions that came with the option.
v
The option is installed correctly.
v
You have not loosened any other installed devices or cables.
v
You updated the configuration information in the Configuration/Setup Utility
program. Whenever memory or any other device is changed, you must
update the configuration.
2. If the option comes with its own test instructions, use those instructions to test
the option.
3. Reseat the device that you just installed.
4. Replace the device that you just installed.
Power error messages
v
Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 8850,” on page 53 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Message
Action
System Power Good fault
1. Check the BladeCenter unit power. (See the
Hardware
Maintenance Manual and Troubleshooting Guide
or
Problem
Determination and Service Guide
for your BladeCenter unit type
for details.)
2. Reseat the blade server.
3. Replace the blade server.
VRM Power Good fault
1. Check the BladeCenter unit power. (See the
Hardware
Maintenance Manual and Troubleshooting Guide
or
Problem
Determination and Service Guide
for your BladeCenter unit type
for details.)
2. Reseat the blade server.
3. Replace the blade server.
System over recommended voltage for +12v. 1. Check the BladeCenter unit power. (See the
Hardware
Maintenance Manual and Troubleshooting Guide
or
Problem
Determination and Service Guide
for your BladeCenter unit type
for details.)
2. Reseat the blade server.
3. Replace the blade server.
Chapter 2. Diagnostics
35
Summary of Contents for LS20 - BladeCenter - 8850
Page 1: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 2: ......
Page 3: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 14: ...xii AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 72: ...58 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 104: ...90 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 114: ...100 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 115: ......
Page 116: ...Part Number 49Y0167 Printed in USA 1P P N 49Y0167...