Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 8850,” on page 53 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
001-250-00n
ECC Test logic Failed. See PCDR logs. n =
failing CPU. [1 - 4]
1.
Restart the server.
2.
Run the diagnostic test again.
3. (Trained service technician only) If problem still
exists, replace the failing microprocessor.
001-292-000
Core system: failed/CMOS checksum failed.
Load the BIOS default settings using the
Configuration/Setup Utility program and run the test
again (see “Configuration/Setup Utility menu choices”
on page 87).
001-xxx-000
Failed core tests.
(Trained service technician only) Replace the system
board assembly.
001-xxx-001
Failed core tests.
(Trained service technician only) Replace the system
board assembly.
005-xxx-000
Failed video test.
(Trained service technician only) Replace the system
board assembly.
030-xxx-000
Failed internal SCSI interface test.
(Trained service technician only) Replace the system
board assembly.
035-xxx-099
No adapters were found.
Reseat the adapter (if installed).
075-xxx-000
Failed power supply test.
Replace the power supply (refer to the
Hardware
Maintenance Manual and Troubleshooting Guide
or
Problem Determination and Service Guide
for your
BladeCenter unit type).
089-xxx-001
Failed microprocessor test.
1. Reseat microprocessor 1.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor 1
b. (Trained service technician only) System
board assembly
089-xxx-002
Failed optional microprocessor test.
1. Reseat microprocessor 2.
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor 2
b. (Trained service technician only) System
board assembly
46
AMD Opteron LS20 Type 8850 for IBM BladeCenter: Problem Determination and Service Guide
Summary of Contents for LS20 - BladeCenter - 8850
Page 1: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 2: ......
Page 3: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 14: ...xii AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 72: ...58 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 104: ...90 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 114: ...100 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 115: ......
Page 116: ...Part Number 49Y0167 Printed in USA 1P P N 49Y0167...