Follow the suggested actions in the order in which they are listed in the Action column until the problem
is solved.
v
See Chapter 3, “Parts listing, Type 8850,” on page 53 to determine which components are customer
replaceable units (CRU) and which components are field replaceable units (FRU).
v
If an action step is preceded by “(Trained service technician only),” that step must be performed only by a
trained service technician.
Error code
Description
Action
662
Diskette drive configuration error.
1. Run the Configuration/Setup Utility program.
2. Reseat the following components:
a. Diskette drive
b. Diskette drive cable
3. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. Diskette drive
b. Diskette drive cable
c. (Trained service technician only) System
board assembly
11xx
System board serial port 1 or 2 error.
1. Reseat the external cable on the serial port.
2. Run the Configuration/Setup Utility program.
3. (Trained service technician only) Replace the
system board assembly.
1162
Serial port configuration conflicts.
1. Run the Configuration/Setup Utility program
ensure that the IRQ and I/O port assignments
needed by the serial port are available.
2. If all interrupts are being used by adapters,
remove an adapter or force other adapters to
share an interrupt.
1200
Processor machine check.
1. Reseat the following components:
a. (Trained service technician only)
Microprocessor 1
b. (Trained service technician only)
Microprocessor 2
2. Replace the following components one at a time,
in the order shown, restarting the server each
time.
a. (Trained service technician only)
Microprocessor 1
b. (Trained service technician only)
Microprocessor 2
c. (Trained service technician only) System
board assembly
1295
ECC circuit check.
(Trained service technician only) Replace the system
board assembly.
22
AMD Opteron LS20 Type 8850 for IBM BladeCenter: Problem Determination and Service Guide
Summary of Contents for LS20 - BladeCenter - 8850
Page 1: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 2: ......
Page 3: ...AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 14: ...xii AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 72: ...58 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 104: ...90 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 114: ...100 AMD Opteron LS20 Type 8850 for IBM BladeCenter Problem Determination and Service Guide...
Page 115: ......
Page 116: ...Part Number 49Y0167 Printed in USA 1P P N 49Y0167...