Complete
the
following
steps
to
perform
the
checkout
procedure:
001
IS
THE
SERVER
PART
OF
A
CLUSTER?
YES.
Schedule
maintenance
for
the
system.
Shut
down
all
systems
related
to
the
cluster.
Run
the
storage
test.
NO.
Go
to
step
002
.
002
IF
THE
SERVER
IS
NOT
PART
OF
A
CLUSTER:
1.
Turn
off
the
server
and
all
external
devices.
2.
Check
all
cables
and
power
cords.
3.
Set
all
display
controls
to
the
middle
position.
4.
Turn
on
all
external
devices.
5.
Turn
on
the
server.
6.
Record
any
POST
error
messages
that
are
displayed
on
the
screen.
If
an
error
is
displayed,
look
up
the
first
error
in
the
“POST
error
codes”
on
page
85.
7.
Check
the
system-error
log.
Note:
The
system-error
log
is
available
only
with
the
Remote
Supervisor
Adapter
II.
If
an
error
was
recorded
by
the
computer,
see
Chapter
6,
“Symptom-to-FRU
index,”
on
page
83.
8.
Start
the
diagnostic
programs.
9.
Check
for
the
following
responses:
v
One
beep
v
Readable
instructions
or
the
main
menu
003
DID
YOU
RECEIVE
BOTH
OF
THE
CORRECT
RESPONSES?
NO.
Find
the
failure
symptom
in
Chapter
6,
“Symptom-to-FRU
index,”
on
page
83.
YES.
Run
the
diagnostic
programs
(see
“Starting
the
diagnostic
programs
and
viewing
the
test
log”
on
page
17).
If
you
receive
an
error,
see
Chapter
6,
“Symptom-to-FRU
index,”
on
page
83.
If
the
diagnostic
programs
were
completed
successfully
and
you
still
suspect
a
problem,
see
“Undetermined
problems”
on
page
113.
Diagnostic
tools
overview
The
following
tools
are
available
to
help
you
diagnose
and
solve
hardware-related
problems:
v
Computer
Support
flowchart
The
Computer
Support
flowchart
on
the
following
page
will
help
you
determine
how
to
get
help
from
IBM
and
register
your
computer.
v
POST
beep
codes
and
error
messages
The
power-on
self-test
generates
beep
codes
and
messages
to
indicate
successful
test
completion
or
the
detection
of
a
problem.
See
“Power-on
self-test
(POST)”
on
page
15
for
more
information.
Additional
information
is
recorded
in
the
post
error
logs.
14
IntelliStation
Z
Pro
Types
6223
and
6227:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for IntelliStation Z Pro 6223
Page 2: ......
Page 145: ...Appendix B Safety information 135...
Page 147: ...Appendix B Safety information 137...
Page 149: ...Appendix B Safety information 139...
Page 151: ...Appendix B Safety information 141...
Page 161: ...Appendix B Safety information 151...
Page 163: ...Appendix B Safety information 153...
Page 179: ......
Page 180: ...Part Number 31R1233 1P P N 31R1233...