Diagnostic
error
LEDs
Lit
LED
FRU/action
DIMM
x
(where
x
=
DIMM
1-6;
see
“System
board
error
LEDs”
on
page
74)
1.
DIMM
x
2.
System
board
Microprocessor
x
(where
x
=
1-2;
see
“System
board
error
LEDs”
on
page
74)
1.
Microprocessor
x
2.
System
board
Fan
x
(where
x
=
1,
2,
or
4;
see
“System
board
error
LEDs”
on
page
74)
Note:
This
feature
is
supported
with
optional
Remote
Supervisor
Adapter
II
only.
1.
Fan
x
2.
System
board
Hard
disk
drive
x
(where
x
=
0-5)
Note:
LEDs
are
located
on
the
front
of
the
hot-swap
hard
disk
drives.
1.
Hard
disk
drive
x
2.
System
board
Error
symptoms
You
can
use
the
error
symptom
table
to
find
solutions
to
problems
that
have
definite
symptoms.
If
you
cannot
find
the
problem
in
the
error
symptom
charts,
run
the
diagnostic
programs
to
test
the
computer.
If
you
have
just
added
new
software
or
a
new
option
and
the
computer
is
not
working,
complete
the
following
steps
before
using
the
error
symptom
charts:
1.
Remove
the
software
or
device
that
you
just
added.
2.
Run
the
diagnostic
tests
to
determine
whether
the
computer
is
running
correctly.
3.
Reinstall
the
new
software
or
new
device.
In
the
following
table,
if
the
entry
in
the
FRU/action
column
is
a
suggested
action,
perform
that
action;
if
it
is
the
name
of
a
component,
reseat
the
component
and
replace
it
if
necessary.
The
most
likely
cause
of
the
symptom
is
listed
first.
Note:
See
Chapter
7,
“Parts
listing
Types
6223
and
6227,”
on
page
115
to
determine
which
components
are
replaceable
by
the
customer
(CRU),
and
which
components
must
be
replaced
by
a
field
service
technician
(FRU).
CD-ROM
drive
Symptom
FRU/action
CD-ROM
drive
is
not
recognized.
1.
Verify
that:
v
The
IDE
channel
to
which
the
CD-ROM
drive
is
attached
(primary
or
secondary)
is
enabled
in
the
Configuration/Setup
Utility
program.
v
All
cables
and
jumpers
are
installed
correctly.
v
The
correct
device
driver
is
installed
for
the
CD-ROM
drive.
2.
Run
CD-ROM
drive
diagnostics.
3.
CD-ROM
drive.
CD
is
not
working
properly.
1.
Clean
the
CD.
2.
Run
CD-ROM
diagnostics.
3.
CD-ROM
drive.
Chapter
6.
Symptom-to-FRU
index
95
Summary of Contents for IntelliStation Z Pro 6223
Page 2: ......
Page 145: ...Appendix B Safety information 135...
Page 147: ...Appendix B Safety information 137...
Page 149: ...Appendix B Safety information 139...
Page 151: ...Appendix B Safety information 141...
Page 161: ...Appendix B Safety information 151...
Page 163: ...Appendix B Safety information 153...
Page 179: ......
Page 180: ...Part Number 31R1233 1P P N 31R1233...