Error
code/symptom
FRU/action
165-060-000
(Service
Processor:
RSA
may
be
busy)
1.
Rerun
the
diagnostic
test.
2.
Fix
other
error
conditions
that
might
be
keeping
the
Remote
Supervisor
Adapter
II
busy.
Refer
to
the
error
log
and
diagnostic
panel.
3.
Disconnect
all
computer
and
option
power
cords
from
the
computer,
wait
30
seconds,
reconnect,
and
retry.
4.
System
board.
.
165-198-000
(Service
Processor:
Aborted)
1.
Rerun
the
diagnostic
test.
2.
Fix
other
error
conditions
that
might
be
keeping
the
Remote
Supervisor
Adapter
II
busy.
Refer
to
the
error
log
and
diagnostic
panel.
3.
Disconnect
all
computer
and
option
power
cords
from
the
computer,
wait
30
seconds,
reconnect,
and
retry.
4.
System
board.
165-201-000
(Service
Processor:
Failed)
1.
Disconnect
all
computer
and
option
power
cords
from
computer,
wait
30
seconds,
reconnect,
and
retry.
2.
System
board.
165-330-000
(Service
Processor:
Failed)
v
Update
to
the
latest
ROM
diagnostic
level,
and
retry.
165-342-000
(Service
Processor:
Failed)
1.
Make
sure
that
the
latest
firmware
levels
for
Remote
Supervisor
Adapter
II
and
BIOS
are
installed.
2.
Disconnect
all
computer
and
option
power
cords
from
computer,
wait
30
seconds,
reconnect,
and
retry.
3.
System
board.
166-198-000
System
Management:
Aborted
(Unable
to
communicate
with
RSA.
It
may
be
busy.
Run
the
test
again.)
1.
Run
the
diagnostic
test
again.
2.
Correct
other
error
conditions
and
retry.
These
include
other
failed
system-management
tests
and
items
that
are
logged
in
the
system-error
log
of
the
optional
Remote
Supervisor
Adapter
II.
3.
Disconnect
all
computer
and
option
power
cords
from
the
computer,
wait
30
seconds,
reconnect,
and
retry.
4.
Remote
Supervisor
Adapter
II.
5.
System
board.
166-201-001
System
Management:
Failed
(I2C
bus
error(s).
See
SERVPROC
and
DIAGS
entries
in
event
log.)
1.
Reseat
the
I2C
cable
between
the
Remote
Supervisor
Adapter
II
and
the
system
board.
2.
Reseat
DIMMs.
3.
DIMMs.
4.
System
board.
166-250-000
System
Management:
Failed
(I2C
cable
is
disconnected.
Reconnect
I2C
cable
between
Remote
Supervisor
Adapter
and
system
board.)
1.
Reseat
the
I2C
cable
between
the
Remote
Supervisor
Adapter
II
and
the
system
board.
2.
Remote
Supervisor
Adapter
II.
3.
System
board.
166-260-000
System
Management:
Failed
(Restart
RSAError.
After
restarting,
RSA
communication
was
lost.)
1.
Disconnect
all
computer
and
option
power
cords
from
the
computer,
wait
30
seconds,
reconnect,
and
retry.
2.
Reseat
the
Remote
Supervisor
Adapter
II.
3.
Remote
Supervisor
Adapter
II.
92
IntelliStation
Z
Pro
Types
6223
and
6227:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for IntelliStation Z Pro 6223
Page 2: ......
Page 145: ...Appendix B Safety information 135...
Page 147: ...Appendix B Safety information 137...
Page 149: ...Appendix B Safety information 139...
Page 151: ...Appendix B Safety information 141...
Page 161: ...Appendix B Safety information 151...
Page 163: ...Appendix B Safety information 153...
Page 179: ......
Page 180: ...Part Number 31R1233 1P P N 31R1233...