Power
error
messages
Note:
See
“System
replaceable
units”
on
page
117
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Message
Action
Power
supply
x
current
share
fault
(level-critical;
excessive
current
demand
on
power
supply
x)
v
Replace
power
supply
x
.
Power
supply
x
DC
good
fault
(level-critical;
power
good
signal
not
detected
for
power
supply
x
)
v
Replace
power
supply
x
.
Power
supply
x
temperature
fault
v
Replace
power
supply
x
.
Power
supply
x
removed
v
No
action
required
–
information
only.
Power
supply
x
fan
fault
(level-critical;
fan
fault
in
power
supply
x
)
v
Replace
power
supply
x
.
Power
supply
x
12
V
fault
(level-critical;
overcurrent
condition
detected)
v
See
“Power
checkout”
on
page
22.
Power
supply
x
3.3
V
fault
(level-critical;
3.3
V
power
supply
x
had
an
error)
v
See
“Power
checkout”
on
page
22.
Power
supply
x
5
V
fault
(level-critical;
5
V
power
supply
x
had
an
error)
v
See
“Power
checkout”
on
page
22.
System
running
non-redundant
power
(level-noncritical;
system
does
not
have
redundant
power)
1.
Add
another
power
supply.
2.
Remove
options
from
system.
3.
System
can
continue
to
operate
without
redundancy
protection
if
steps1
and
2
are
not
followed.
System
under
recommended
voltage
for
x
(level-warning;
indicated
voltage
supply
under
nominal
value;
value
for
x
can
be
+12,
-12,
or
+5)
1.
Check
connections
to
the
power
subsystem.
2.
Power
supply.
3.
Power
cage
assembly,
if
installed.
System
shutdown
See
the
following
tables
when
experiencing
system
shutdown
related
to
voltage
or
temperature
problems.
Voltage-related
system
shutdown
Note:
See
“System
replaceable
units”
on
page
117
to
determine
which
components
should
be
replaced
by
a
field
service
technician.
Message
Action
System
shutoff
due
to
x
current
over
max
value
(level-critical;
system
drawing
too
much
current
on
voltage
x
bus)
v
See
“Power
checkout”
on
page
22.
System
shutoff
due
to
x
V
over
voltage
(level-critical;
system
shutoff
due
to
x
supply
over
voltage)
1.
Check
the
power-supply
connectors.
2.
Power
supply.
3.
Power
cage
assembly,
if
installed.
110
IntelliStation
Z
Pro
Types
6223
and
6227:
Hardware
Maintenance
Manual
and
Troubleshooting
Guide
Summary of Contents for IntelliStation Z Pro 6223
Page 2: ......
Page 145: ...Appendix B Safety information 135...
Page 147: ...Appendix B Safety information 137...
Page 149: ...Appendix B Safety information 139...
Page 151: ...Appendix B Safety information 141...
Page 161: ...Appendix B Safety information 151...
Page 163: ...Appendix B Safety information 153...
Page 179: ......
Page 180: ...Part Number 31R1233 1P P N 31R1233...