POST message
Description
289
An error occurred during POST memory tests and a failing DIMM was disabled.
Note:
The server can be used with decreased memory.
Action:
1. If you just installed memory, see “Installing DIMMs and memory boards” on
page 52 to verify that the new memory is correct for your server. Verify that the
DIMMs are installed and seated correctly.
2. Check to see if the error logs in the Configuration/Setup Utility program provide
additional information on the error.
3. If the problem persists, replace the failing DIMM.
If the problem persists, have the system serviced.
301
303
An error occurred during the keyboard and keyboard controller test. These error
messages also might be accompanied by continuous beeping.
Action:
1. If you have just connected a new mouse or other pointing device, turn off the
server and disconnect that device. Wait at least five seconds, and then turn on
the server. If the error message goes away, replace the device.
2. Ensure that:
a. Nothing is resting on the keyboard and pressing a key.
b. No key is stuck.
c. The keyboard cable is connected correctly to the keyboard and to the
correct connector on the server.
3. Attach another keyboard to the keyboard connector.
4. Running the diagnostic tests can isolate the server component that failed, but
you must have your system serviced. If the error message remains, have the
keyboard, cable, and system serviced.
602
The diskette has an invalid startup (boot) record.
Action:
1. Verify that the Configuration/Setup Utility program correctly reflects the type of
diskette drive that you have installed.
2. Verify that the diskette is a startable (bootable) diskette.
3. Remove the diskette from the diskette drive, and install a different startable
(bootable) diskette.
4. Run the diagnostic tests on the diskette drive.
If the diagnostic tests fail, have the system serviced.
604
An error occurred during a diskette drive test.
Action:
1. Verify that the Configuration/Setup Utility program correctly reflects the type of
diskette drive that you have installed.
2. Run the diagnostic tests on the diskette drive.
If the diagnostic tests fail, have the system serviced.
605
A diskette unlock error occurred.
Action:
Run the diagnostic tests on the diskette drive.
If the diagnostic tests fail, have the system serviced.
662
A diskette drive configuration error occurred.
Action:
If you removed a diskette drive, make sure that the diskette drive setting is
correct in the Configuration/Setup Utility program. If the setting is not correct,
change it. For information on using the Configuration/Setup Utility program, see
“Using the Configuration/Setup Utility main menu” on page 21.
If the problem persists, have the system serviced.
136