016 (continued)
– The Advanced Diagnostics did not detect a failure. If the system still
displays a failure:
Check all adapter card jumper settings.
Check all adapter card switch settings.
Check all adapter card cables and connectors for proper installation.
Make sure all of the above are set correctly and show the correct
voltages and continuity. Replace any defective cables or adapter
cards. See “Power Supply” on page 2-26 and “System Board
Layout—Type
I
-1” on page 5-2 and “System Board Layout—Type
I
-2” on page 5-5.
– Run the Advanced Diagnostics for All Devices with the 0 (RUN TESTS
ONE TIME) option.
– If an error or other symptom is displayed, go to “Index of Symptoms,
Messages, Error Codes, or Beeps” on page 2-10.
– If no error can be detected or the symptom is intermittent, start an error
log. See “Error Log for Intermittent Problems” on page 3-10.
Check Procedures
2-9