006 (continued)
ARE THE VOLTAGES CORRECT AND DOES THE FAN RUN?
Yes No
007
Replace the power supply.
008
– The power supply is working normally. (If you suspect the on/off switch
cable assembly, see Step 009.) If the fan continues to run when all
connectors are plugged back in, go to “Undetermined Problem” on
page 2-70. If the fan stops running when a drive connector is plugged
back in, go to “Factory-Installed Drive Devices” on page 2-46.
009
(From steps 003 and 008)
DOES THE SYSTEM UNIT FAIL TO SHUT OFF WHEN THE ON/OFF
SWITCH IS PRESSED?
Yes No
010
Go to Step 006 on page 2-35.
011
– You might have a failing on/off switch cable assembly.
– Disconnect the on/off switch cable assembly connector from the power
supply connector and take an ohm reading.
DO YOU HAVE AN OHM READING WHEN THE SWITCH IS PRESSED
AND AN OPEN READING WHEN THE SWITCH IS RELEASED?
Yes No
012
– Replace the on/off switch cable assembly.
013
– Replace the system board.
Check Procedures
2-37
Summary of Contents for Aptiva 2134
Page 2: ......
Page 22: ...xx...
Page 24: ...xxii...
Page 144: ...3 18...
Page 166: ...Drive Front View Figure 4 22 Bay 4 3 5 In 4 22...
Page 220: ...6 2...
Page 224: ...Assembly 2 Machine Type 2134 System Unit Interior SL A 5 4 3 8 7 6 1 10 2 9 12 11 7 4...
Page 231: ...Assembly 5 Diskette Hard Disk Drives and Internal Zip Drive 3 1 4 4 4 2 Parts Catalog 7 11...
Page 233: ...Assembly 6 CD ROM Drive Mwave Sound TV and Modem Cards 3 5 8 1 2 4 6 7 Parts Catalog 7 13...
Page 242: ...7 22...
Page 246: ...Part Asm Number Index Page 96G3122 7 1 7 17 96G3123 7 1 7 17 96G3124 7 1 7 17 8 4...
Page 265: ......