SRN
Problem
Possible Causes
49520
Description: Hot-spare tuning has been lost.
Action:
1. Type
smitty ssaraid
and press Enter.
2. Select List Status of Hot-Spare Pools.
3. Select the adapter that logged the error. If the adapter is not known,
select all adapters.
4. Note the RAID Manager (adapter) and pool number of spare-pools
that have a status of mixed.
5. Select List Components in a Hot-Spare Pool.
6. Select the RAID Manager and pool that you noted earlier.
7. Note the array name (hdisk) and member disk drive (pdisk) that have
a status of wrong_pool. (This array member disk drive (pdisk) is
exchanged later, after all rejected disk drives have been exchanged.)
8. Select Change/Show Use of an SSA Physical Disk, and select the
RAID manager that you noted earlier.
9. Note all the disk drives that are listed as rejected.
10. Exchange all failed and rejected disk drives for new disk drives.
11. Select Change/Show Use of Multiple SSA Physical Disks.
12. Change the Current Use parameter of the exchanged disk drives to
Hot Spare Disks.
13. If the user has a record of how disk drives are assigned to the
hot-spare pools, use that information to assign the hot spare disk
drives to the correct pools.
If the user has no such record, see “Deciding how to Configure Hot
Spare Disk Drive Pools” on page 45 to determine the best hot-spare
configuration, then go to step 14.
14. Select Change/Show/Delete a Hot-Spare Pool.
15. Add the hot spare disk drives to the correct pool (see “Adding Disks
to, or Removing Disks from, a Hot Spare Pool” on page 86).
16. Select Change Member Disks in an SSA RAID Array.
17. Swap the pdisk, whose name you noted in step 7, with a hot spare
disk drive that is in the pool that you noted in step 4 (see “Changing
Member Disks in an SSA RAID Array” on page 137).
Note: If the customer chooses not to have the disk drive swapped,
the only way to clear this error condition is to remove all the member
disk drives from this hot spare pool, then recreate the pool. If you
do these actions, you change the configuration of the hot spare
pool.
18. Select Change/Show Use of an SSA Physical Disk.
19. Change to Hot Spare Disk the Current Use parameter of the disk
drive (pdisk) whose name you noted in step 7.
20. Select Change/Show/Delete a Hot-Spare Pool.
21. Add to the correct pool the hot spare disk drive that you created in
step 19.
An array member has used a
hot spare disk drive from a pool
other than its specified pool. If
the hot-spare pools have been
correctly configured, this error
indicates that more than one
disk drive might have failed.
Possible FRUs:
Device (100%)
(“Exchanging Disk Drives”
on page 319).
432
User’s Guide and Maintenance Information
Summary of Contents for Advanced SerialRAID Adapters SA33-3285-02
Page 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 2: ......
Page 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 16: ...xiv User s Guide and Maintenance Information ...
Page 18: ...xvi User s Guide and Maintenance Information ...
Page 21: ...Part 1 User Information 1 ...
Page 22: ...2 User s Guide and Maintenance Information ...
Page 48: ...28 User s Guide and Maintenance Information ...
Page 64: ...44 User s Guide and Maintenance Information ...
Page 76: ...56 User s Guide and Maintenance Information ...
Page 212: ...192 User s Guide and Maintenance Information ...
Page 228: ...208 User s Guide and Maintenance Information ...
Page 230: ...210 User s Guide and Maintenance Information ...
Page 254: ...234 User s Guide and Maintenance Information ...
Page 274: ...254 User s Guide and Maintenance Information ...
Page 330: ...310 User s Guide and Maintenance Information ...
Page 331: ...Part 2 Maintenance Information 311 ...
Page 332: ...312 User s Guide and Maintenance Information ...
Page 338: ...318 User s Guide and Maintenance Information ...
Page 430: ...410 User s Guide and Maintenance Information ...
Page 503: ...Part 3 Appendixes 483 ...
Page 504: ...484 User s Guide and Maintenance Information ...
Page 508: ...488 User s Guide and Maintenance Information ...
Page 529: ......
Page 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Page 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...