SRN
Problem
Possible Causes
49950
Description: An array copy disk drive is missing. The array copy is
degraded. If the missing disk drive is restored to the network or
exchanged for a new disk drive, the copy rebuilds. A disk drive might not
be available for one of the following reasons:
v
The disk drive has failed.
v
The disk drive has been removed from the subsystem.
v
An SSA link has failed.
v
A power failure has occurred.
Action: Go to “MAP 2324: SSA RAID” on page 454.
Possible FRUs:
Device (100%)
(“Exchanging Disk Drives”
on page 319).
4A100
Description: The adapter cannot initialize a disk drive. The failing disk
drive might, or might not, be configured on this system.
Action: Run diagnostics in System Verification mode to all pdisks.
If the diagnostics fail, exchange the pdisk for a new disk drive.
If the diagnostics do not detect a failing pdisk, use the Link Verification
service aid (see “Link Verification Service Aid” on page 383) to search for
disk drives that are not configured. Such disk drives are listed as *****.
Note: Other adapters in the SSA loop might also be listed as *****.
Exchange, for new disk drives, all pdisks that are not configured.
Possible FRUs:
Device (100%)
(“Exchanging Disk Drives”
on page 319).
4BPAA
Description: A disk drive at PAA cannot be configured, because its UID
cannot be read.
Action: If the SSA service aids are available:
1. Run the Link Verification service aid (see “Link Verification Service
Aid” on page 383) to find the failing device. The service aid lists the
device as
*****
.
2. Exchange the FRU for a new FRU.
If the service aids are not available:
1. Note the value of PAA in this SRN, then go to “Finding the Physical
Location of a Device” on page 409.
2. Exchange the FRU for a new FRU.
Possible FRUs:
Device (100%)
(“Exchanging Disk Drives”
on page 319).
50000
Description: The SSA adapter failed to respond to the device driver.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
50001
Description: A data parity error has occurred.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
434
User’s Guide and Maintenance Information
||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Summary of Contents for Advanced SerialRAID Adapters SA33-3285-02
Page 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 2: ......
Page 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 16: ...xiv User s Guide and Maintenance Information ...
Page 18: ...xvi User s Guide and Maintenance Information ...
Page 21: ...Part 1 User Information 1 ...
Page 22: ...2 User s Guide and Maintenance Information ...
Page 48: ...28 User s Guide and Maintenance Information ...
Page 64: ...44 User s Guide and Maintenance Information ...
Page 76: ...56 User s Guide and Maintenance Information ...
Page 212: ...192 User s Guide and Maintenance Information ...
Page 228: ...208 User s Guide and Maintenance Information ...
Page 230: ...210 User s Guide and Maintenance Information ...
Page 254: ...234 User s Guide and Maintenance Information ...
Page 274: ...254 User s Guide and Maintenance Information ...
Page 330: ...310 User s Guide and Maintenance Information ...
Page 331: ...Part 2 Maintenance Information 311 ...
Page 332: ...312 User s Guide and Maintenance Information ...
Page 338: ...318 User s Guide and Maintenance Information ...
Page 430: ...410 User s Guide and Maintenance Information ...
Page 503: ...Part 3 Appendixes 483 ...
Page 504: ...484 User s Guide and Maintenance Information ...
Page 508: ...488 User s Guide and Maintenance Information ...
Page 529: ......
Page 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Page 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...