Chapter 14. SSA Adapter Information
For a description of the SSA adapter, port addresses, and the rules for SSA loops, see
Chapter 1, “Introducing SSA and the Advanced SerialRAID Adapters”.
Installing the SSA Adapter
1. Install the adapter and disk drive microcode from the media that are supplied with
the adapter. A README sheet of installation instructions is also supplied.
2. Install the adapter into a slot in the using system (see the Installation and Service
Guide for the using system).
3. Switch on the using system. This action ensures that the latest version of the
microcode that is available on the using system is downloaded into the adapter
before the disk drives are connected.
4. Connect the SSA cables to the adapter and to the devices that are to be attached
to the adapter. For information about how the cables are to be attached, see the
configuration plan that was created when the subsystem was ordered.
If the configuration plan is not available, use the example configuration information
that is given in the service information for the devices.
See also Chapter 2, “Introducing SSA Loops” on page 7 for general information
about SSA loops and links.
Note: If, for any reason, an adapter is exchanged for a replacement adapter, all
associated arrays that were not synchronized when the adapter failed are rebuilt.
Cron Table Entries
During the installation of the SSA software, the following four entries are made in the
system cron table:
01 5 * * * /usr/lpp/diagnostics/bin/run_ssa_ela 1>/dev/null 2>/dev/null
0 * * * * /usr/lpp/diagnostics/bin/run_ssa_healthcheck 1>/dev/null 2>/dev/null
30 * * * * /usr/lpp/diagnostics/bin/run_ssa_encl_healthcheck 1>/dev/null 2/dev/null
30 4 * * * /usr/lpp/diagnostics/bin/run_ssa_link_speed 1>/dev/null 2>/dev/null
The first entry instructs the run_ssa_ela shell script to run at 05:01 each day. This shell
script analyzes the error log. If it finds any problems, the script warns the user in the
following ways. It sends:
v
An error message to /dev/console. This message is displayed on the system console.
v
An OPMSG to the error log. This message indicates the source of the error.
v
A mail message to ssa_adm.
Note: ssa_adm is an alias mail address that is set up in /etc/aliases. By default, the
address is set to “root”, but you can set it to any valid mail address for the
using system.
313
Summary of Contents for Advanced SerialRAID Adapters SA33-3285-02
Page 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 2: ......
Page 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 16: ...xiv User s Guide and Maintenance Information ...
Page 18: ...xvi User s Guide and Maintenance Information ...
Page 21: ...Part 1 User Information 1 ...
Page 22: ...2 User s Guide and Maintenance Information ...
Page 48: ...28 User s Guide and Maintenance Information ...
Page 64: ...44 User s Guide and Maintenance Information ...
Page 76: ...56 User s Guide and Maintenance Information ...
Page 212: ...192 User s Guide and Maintenance Information ...
Page 228: ...208 User s Guide and Maintenance Information ...
Page 230: ...210 User s Guide and Maintenance Information ...
Page 254: ...234 User s Guide and Maintenance Information ...
Page 274: ...254 User s Guide and Maintenance Information ...
Page 330: ...310 User s Guide and Maintenance Information ...
Page 331: ...Part 2 Maintenance Information 311 ...
Page 332: ...312 User s Guide and Maintenance Information ...
Page 338: ...318 User s Guide and Maintenance Information ...
Page 430: ...410 User s Guide and Maintenance Information ...
Page 503: ...Part 3 Appendixes 483 ...
Page 504: ...484 User s Guide and Maintenance Information ...
Page 508: ...488 User s Guide and Maintenance Information ...
Page 529: ......
Page 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Page 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...