each side of the indicated physical so that the disk can be removed from the
loop for service, and no errors are caused on the loops.
This flag has support only for SSA physical disk drives. You cannot specify this
flag and the SSADISK_SCSIMODE flag together.
SSADISK_SCSIMODE
Opens an SSA physical disk in SCSI passthrough mode. This action allows
SSADISK_IOCTL_SCSI ioctls to be issued to the physical disk.
This flag has support only for SSA physical disk drives. You cannot specify this
flag and the SSADISK_SERVICEMODE flag together.
SSADISK_NORETRY
Opens a device in no-retry mode.
When a device is opened in this mode, commands are not retried if an error
occurs.
SSADISK_FENCEMODE
Opens an SSA logical disk drive in fence mode. The open subroutine
succeeds although the using system might be fenced out from access to the
disk drive. Only ioctls can be issued to the device while it is open in this mode.
Any attempt to read from, or write to, a device that is opened in this mode is
rejected with an error.
This flag has support only for SSA logical disk drives. You cannot specify this
flag and the SSADISK_NO_RESERVE flag, SSADISK_FORCED_OPEN flag,
or SSADISK_RETAIN_RESERVATION flag together.
You can find more specific information about the open operations in “SSA Options to
the openx Subroutine” in the Kernel Extensions and Device Support Programming
Concepts manuals for AIX versions 4.1 and upward.
readx and writex Subroutines
The readx and writex subroutines provide additional parameters that affect the transfer
of raw data (that is, data that has not been processed or reduced). These subroutines
pass the ext parameter, which specifies request options. The options are constructed by
logically ORing zero or more of the following values:
HWRELOC
Request for hardware relocation that is safe.
UNSAFEREL
Request for hardware relocation that is not safe.
WRITEV
Request for write verification.
Error Conditions
Possible errno values that occur for ioctl, open, read, and write subroutines when the
SSA disk device driver is used include:
EBUSY
One of the following conditions has occurred:
274
User’s Guide and Maintenance Information
Summary of Contents for Advanced SerialRAID Adapters SA33-3285-02
Page 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 2: ......
Page 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 16: ...xiv User s Guide and Maintenance Information ...
Page 18: ...xvi User s Guide and Maintenance Information ...
Page 21: ...Part 1 User Information 1 ...
Page 22: ...2 User s Guide and Maintenance Information ...
Page 48: ...28 User s Guide and Maintenance Information ...
Page 64: ...44 User s Guide and Maintenance Information ...
Page 76: ...56 User s Guide and Maintenance Information ...
Page 212: ...192 User s Guide and Maintenance Information ...
Page 228: ...208 User s Guide and Maintenance Information ...
Page 230: ...210 User s Guide and Maintenance Information ...
Page 254: ...234 User s Guide and Maintenance Information ...
Page 274: ...254 User s Guide and Maintenance Information ...
Page 330: ...310 User s Guide and Maintenance Information ...
Page 331: ...Part 2 Maintenance Information 311 ...
Page 332: ...312 User s Guide and Maintenance Information ...
Page 338: ...318 User s Guide and Maintenance Information ...
Page 430: ...410 User s Guide and Maintenance Information ...
Page 503: ...Part 3 Appendixes 483 ...
Page 504: ...484 User s Guide and Maintenance Information ...
Page 508: ...488 User s Guide and Maintenance Information ...
Page 529: ......
Page 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Page 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...