v
Change the state of the Split Array Resolution flag on the new adapters.
Attention:
This method helps you to recover the system from severe errors. Use
this method only if the other half of the array has failed completely, and will never be
used again.
Array is Offline because the Split and Join Procedure Was Not Performed
Correctly
When this condition occurs, the host system generates SRN 48760.
The condition can be caused if a RAID-1 or a RAID-10 array has been split exactly in
half, and a separate write operation has been performed to each half of the array.
This problem can occur in a dual-host configuration if:
v
Only one adapter can be detected on the SSA loop, you change the state of the Split
Array Resolution flag, and a separate write operation is performed to each half of the
array.
v
Both adapters can be detected on the SSA loop, but one half of the RAID array
cannot be detected, and the following sequence of events occurs:
1. A write operation is performed.
2. The half of the array that could originally be detected can no longer be detected.
3. The half of the array that could not originally be detected can now be detected,
and data is written to it.
4. The half of the array that could originally be detected can now be detected again.
The problem can also occur in a single-host system if only one half of the RAID array
can be detected, and the following sequence of events occurs:
1. A write operation is performed.
2. The half of the array that could not originally be detected can now be detected.
3. The half of the array that could originally be detected can no longer be detected,
and data is written to it.
4. The half of the array that could originally be detected can now be detected again.
Chapter 8. Split-Site Management
205
Summary of Contents for Advanced SerialRAID Adapters SA33-3285-02
Page 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 2: ......
Page 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 16: ...xiv User s Guide and Maintenance Information ...
Page 18: ...xvi User s Guide and Maintenance Information ...
Page 21: ...Part 1 User Information 1 ...
Page 22: ...2 User s Guide and Maintenance Information ...
Page 48: ...28 User s Guide and Maintenance Information ...
Page 64: ...44 User s Guide and Maintenance Information ...
Page 76: ...56 User s Guide and Maintenance Information ...
Page 212: ...192 User s Guide and Maintenance Information ...
Page 228: ...208 User s Guide and Maintenance Information ...
Page 230: ...210 User s Guide and Maintenance Information ...
Page 254: ...234 User s Guide and Maintenance Information ...
Page 274: ...254 User s Guide and Maintenance Information ...
Page 330: ...310 User s Guide and Maintenance Information ...
Page 331: ...Part 2 Maintenance Information 311 ...
Page 332: ...312 User s Guide and Maintenance Information ...
Page 338: ...318 User s Guide and Maintenance Information ...
Page 430: ...410 User s Guide and Maintenance Information ...
Page 503: ...Part 3 Appendixes 483 ...
Page 504: ...484 User s Guide and Maintenance Information ...
Page 508: ...488 User s Guide and Maintenance Information ...
Page 529: ......
Page 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Page 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...