SRN
Problem
Possible Causes
34000
Description: The adapter cannot initialize a device. This problem might be
badly affecting the SSA loop. If the device was a member of a RAID
array, you might not be able to list this disk drive by using the RAID
facilities.
Action: Exchange the FRUs for new FRUs.
Possible FRUs:
Device (90%) (“Exchanging
Disk Drives” on page 319).
External SSA cables (5%)
Internal SSA connections
(5%) (enclosure service
information)
35000
Description: Loop problems are causing the adapter to try to reset disk
drives.
Action: Check the log for other error information, including other 35000
errors, that might indicate which section of the loop is causing the
problems.
Possible FRUs:
External SSA cables
(30%).
Internal SSA connections
(30%) (enclosure service
information).
Device (30%) (“Exchanging
Disk Drives” on page 319).
SSA adapter card (10%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
40000
Description: The SSA adapter card has failed.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
40016
Description: A 16 MB SDRAM in the adapter card module has failed.
Action: Exchange the FRUs for new FRUs.
Possible FRUs:
16 MB SDRAM module
(99%) (“Removing an
SDRAM Module of an
Advanced SerialRAID
Adapter” on page 329).
SSA adapter card (1%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
40064
Description: A 64 MB SDRAM in the adapter card module has failed.
Action: Exchange the FRUs for new FRUs.
Possible FRUs:
64 MB SDRAM module
(99%) (“Removing an
SDRAM Module of an
Advanced SerialRAID
Adapter” on page 329).
SSA adapter card (1%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
Chapter 18. SSA Problem Determination Procedures
415
::
:
:
:
:
:
:
:
:
:
:
:
:
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Summary of Contents for Advanced SerialRAID Adapters SA33-3285-02
Page 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 2: ......
Page 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 16: ...xiv User s Guide and Maintenance Information ...
Page 18: ...xvi User s Guide and Maintenance Information ...
Page 21: ...Part 1 User Information 1 ...
Page 22: ...2 User s Guide and Maintenance Information ...
Page 48: ...28 User s Guide and Maintenance Information ...
Page 64: ...44 User s Guide and Maintenance Information ...
Page 76: ...56 User s Guide and Maintenance Information ...
Page 212: ...192 User s Guide and Maintenance Information ...
Page 228: ...208 User s Guide and Maintenance Information ...
Page 230: ...210 User s Guide and Maintenance Information ...
Page 254: ...234 User s Guide and Maintenance Information ...
Page 274: ...254 User s Guide and Maintenance Information ...
Page 330: ...310 User s Guide and Maintenance Information ...
Page 331: ...Part 2 Maintenance Information 311 ...
Page 332: ...312 User s Guide and Maintenance Information ...
Page 338: ...318 User s Guide and Maintenance Information ...
Page 430: ...410 User s Guide and Maintenance Information ...
Page 503: ...Part 3 Appendixes 483 ...
Page 504: ...484 User s Guide and Maintenance Information ...
Page 508: ...488 User s Guide and Maintenance Information ...
Page 529: ......
Page 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Page 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...