SRN
Problem
Possible Causes
50002
Description: An SSA adapter DMA error has occurred.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
50007
Description: The IOCC detected an internal error.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
50008
Description: Unable to read or write the POS registers or PCI
configuration space.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
50010
Description: An SSA adapter or device drive protocol error has occurred.
Action: Go to “Software and Microcode Errors” on page 441 before
exchanging the FRU.
Possible FRUs:
SSA adapter card (100%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
50012
Description: The SSA adapter microcode has hung.
Action: Run diagnostics in System Verification mode to the SSA adapter.
If the diagnostics fail, exchange the FRU for a new FRU.
If the diagnostics do not fail, go to “Software and Microcode Errors” on
page 441 before exchanging the FRU.
Possible FRUs:
SSA adapter card (100%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
50013
Description: The SSA adapter card has failed.
Action: Exchange the FRU for a new FRU.
Possible FRUs:
SSA adapter card (100%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
50100
Description: An attempt was made to log an error against a pdisk that is
not available to the using system.
Action: This problem has occurred for one of the following reasons:
v
A user has deleted a pdisk from the system configuration. In such an
instance, the hdisk that is using the pdisk continues to operate
normally. If the disk drive tries to log an error, however, this SRN
(50100) is produced. Give the cfgmgr command to return the pdisk to
the system configuration.
v
A device has tried to log an error during system configuration. To find
the failing device, run diagnostics to the devices that are connected to
this SSA adapter.
Disk drive error during system
configuration.
Chapter 18. SSA Problem Determination Procedures
435
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Summary of Contents for Advanced SerialRAID Adapters SA33-3285-02
Page 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 2: ......
Page 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 16: ...xiv User s Guide and Maintenance Information ...
Page 18: ...xvi User s Guide and Maintenance Information ...
Page 21: ...Part 1 User Information 1 ...
Page 22: ...2 User s Guide and Maintenance Information ...
Page 48: ...28 User s Guide and Maintenance Information ...
Page 64: ...44 User s Guide and Maintenance Information ...
Page 76: ...56 User s Guide and Maintenance Information ...
Page 212: ...192 User s Guide and Maintenance Information ...
Page 228: ...208 User s Guide and Maintenance Information ...
Page 230: ...210 User s Guide and Maintenance Information ...
Page 254: ...234 User s Guide and Maintenance Information ...
Page 274: ...254 User s Guide and Maintenance Information ...
Page 330: ...310 User s Guide and Maintenance Information ...
Page 331: ...Part 2 Maintenance Information 311 ...
Page 332: ...312 User s Guide and Maintenance Information ...
Page 338: ...318 User s Guide and Maintenance Information ...
Page 430: ...410 User s Guide and Maintenance Information ...
Page 503: ...Part 3 Appendixes 483 ...
Page 504: ...484 User s Guide and Maintenance Information ...
Page 508: ...488 User s Guide and Maintenance Information ...
Page 529: ......
Page 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Page 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...