21. (from step 1)
No spare disk drives are available for an array that is configured for hot spare disk
drives.
a. If the subsystem contains disk drives that have failed, repair those disk drives,
or exchange them for new disk drives (see “Exchanging Disk Drives” on
page 319).
b. Type
smitty ssaraid
and press Enter.
c. Select Change/Show Use of an SSA Physical Disk.
Are any disks listed as “SSA Physical disks that are hot spares”?
NO
Review with the user the requirement for hot spare disk drives. If the
customer wants hot spare disk drives, one or more disk drives must have
their use changed to Hot Spare Disk.
If the customer does not want hot spare disk drives:
a. Return to the SSA RAID Arrays menu.
b. Select Change/Show Attributes of an SSA RAID Array.
c. Change the Enable Use of Hot Spares attribute to No.
YES
The following conditions must be met to make a hot spare disk drive
available for use by an array:
v
The hot spare disk drive and the array must be on the same SSA loop
(see “Creating a Hot Spare Disk Drive” on page 72).
v
If the spare_exact parameter is set to true, the size of the hot spare
disk drive must be the same as the size of the smallest member disk
drive in the array. (See “Changing or Showing the Attributes of an SSA
RAID Array” on page 135 to determine how the hot spare attribute is
set; see “Listing the Disk Drives in an SSA RAID Array” on page 109 to
determine the sizes of the disk drives that are in the array.)
v
If the spare_exact parameter is set to false, the size of the hot spare
disk drive must be at least that of the smallest member disk in the
array.
a. Ensure that these conditions have been met.
b. Go to “MAP 2410: SSA Repair Verification” on page 475 to verify the
repair.
466
User’s Guide and Maintenance Information
Summary of Contents for Advanced SerialRAID Adapters SA33-3285-02
Page 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 2: ......
Page 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 16: ...xiv User s Guide and Maintenance Information ...
Page 18: ...xvi User s Guide and Maintenance Information ...
Page 21: ...Part 1 User Information 1 ...
Page 22: ...2 User s Guide and Maintenance Information ...
Page 48: ...28 User s Guide and Maintenance Information ...
Page 64: ...44 User s Guide and Maintenance Information ...
Page 76: ...56 User s Guide and Maintenance Information ...
Page 212: ...192 User s Guide and Maintenance Information ...
Page 228: ...208 User s Guide and Maintenance Information ...
Page 230: ...210 User s Guide and Maintenance Information ...
Page 254: ...234 User s Guide and Maintenance Information ...
Page 274: ...254 User s Guide and Maintenance Information ...
Page 330: ...310 User s Guide and Maintenance Information ...
Page 331: ...Part 2 Maintenance Information 311 ...
Page 332: ...312 User s Guide and Maintenance Information ...
Page 338: ...318 User s Guide and Maintenance Information ...
Page 430: ...410 User s Guide and Maintenance Information ...
Page 503: ...Part 3 Appendixes 483 ...
Page 504: ...484 User s Guide and Maintenance Information ...
Page 508: ...488 User s Guide and Maintenance Information ...
Page 529: ......
Page 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Page 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...