27. (from step 22)
Is any disk drive failing?
NO
A disk drive that is listed as rejected is not necessarily failing. For
example, the array might have rejected the disk drive because a power
problem, or an SSA link problem, caused that drive to become temporarily
unavailable. Under such conditions, the disk drive can be reused.
If you think that a disk drive has been rejected because it is failing, check
the error log history for that disk drive. For example, if you suspect
pdisk3, type on the command line:
ssa_ela -l pdisk3 -h 5
This command causes the error log for pdisk3 to be analyzed for the
previous five days. If a problem is detected, an SRN is generated.
Go to step 28.
YES
a. Exchange the failing disk drive for a new one (see “Exchanging Disk
Drives” on page 319).
b. Go to step 37 on page 473 to add the disk drive to the group of disk
drives that are available for use by the RAID manager.
28. (from steps 22 and 27)
a. Type
smitty ssaraid
and press Enter.
b. Select List All SSA RAID Arrays Connected to a RAID Manager.
c. List the arrays that are connected to each SSA Adapter.
Are any arrays listed with a status other than Good or Rebuilding?
NO
Go to step 29.
YES
Go to step 1 on page 454.
29. (from steps 28 and 35)
a. Type
smitty ssaraid
and press Enter.
b. Select List Status Of All Defined SSA RAID Arrays.
c. Select, in turn, each type of array that is used on your subsystem, and press
Enter.
Do any listed arrays have Invalid Data Strips?
NO
Go to step 30 on page 471.
YES
Go to step 1 on page 454.
470
User’s Guide and Maintenance Information
|
Summary of Contents for Advanced SerialRAID Adapters SA33-3285-02
Page 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 2: ......
Page 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 16: ...xiv User s Guide and Maintenance Information ...
Page 18: ...xvi User s Guide and Maintenance Information ...
Page 21: ...Part 1 User Information 1 ...
Page 22: ...2 User s Guide and Maintenance Information ...
Page 48: ...28 User s Guide and Maintenance Information ...
Page 64: ...44 User s Guide and Maintenance Information ...
Page 76: ...56 User s Guide and Maintenance Information ...
Page 212: ...192 User s Guide and Maintenance Information ...
Page 228: ...208 User s Guide and Maintenance Information ...
Page 230: ...210 User s Guide and Maintenance Information ...
Page 254: ...234 User s Guide and Maintenance Information ...
Page 274: ...254 User s Guide and Maintenance Information ...
Page 330: ...310 User s Guide and Maintenance Information ...
Page 331: ...Part 2 Maintenance Information 311 ...
Page 332: ...312 User s Guide and Maintenance Information ...
Page 338: ...318 User s Guide and Maintenance Information ...
Page 430: ...410 User s Guide and Maintenance Information ...
Page 503: ...Part 3 Appendixes 483 ...
Page 504: ...484 User s Guide and Maintenance Information ...
Page 508: ...488 User s Guide and Maintenance Information ...
Page 529: ......
Page 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Page 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...