SRN
Problem
Possible Causes
504XX
Description: The SSA adapter microcode has hung.
Action: Run diagnostics in System Verification mode to the SSA adapter.
If the diagnostics fail, exchange the FRU for a new FRU. If the
diagnostics do not fail, go to “Software and Microcode Errors” on
page 441.
Software error.
Possible FRUs:
SSA adapter card (100%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
54050
Description: The adapter bus has been reset.
Action: Exchange the FRUs for new FRUs.
Possible FRUs:
SSA adapter card (60%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
Using-system board (40%)
(using-system service
information)
60000
Description: The SSA adapter is missing from the expected configuration.
Action: Verify that the SSA adapter card is installed in the expected slot of
the using system.
If it is in the expected slot, exchange the FRU for a new FRU.
If it is not in the expected slot, give the diag -a command, and answer the
questions that are displayed.
Possible FRUs:
SSA adapter card (100%)
(“Removing and Replacing
an Advanced SerialRAID
Adapter” on page 327).
60200
60210
Description: SRNs in this range are not adapter SRNs.
Action: For SRNs in this range, see the documentation for your SSA
enclosure or SSA subsystem.
Not applicable.
60240
Description: A configuration problem has occurred. A device cannot be
configured, for some unknown reason.
Action: Go to the START MAP for the enclosure in which the device is
installed. If no problem is found, go to “Software and Microcode Errors” on
page 441.
Software error.
SSA loop configuration
problem.
7XXXX
Description: An SSA device is missing from the expected configuration of
the SSA loop.
Action: Go to the service information for the enclosure in which the
missing device should be installed.
Note: In this SRN, an X represents a digit 0 through F.
An SSA enclosure diagnostic
has detected a missing disk
drive.
8XXXX
Description: SRNs in this range are used by the SSA enclosure
(subsystem).
Action: Go to the service information for your SSA enclosure.
Note: In this SRN, an X represents a digit 0 through F.
Not applicable.
D0000
to
D0FFF
Description: SRNs in this range are not adapter SRNs.
Action: For SRNs in this range, see the documentation for your SSA
enclosure or SSA subsystem.
Not applicable.
Chapter 18. SSA Problem Determination Procedures
437
|
|
|
|
::
:
:
|
|
|
|
:
:
:
|
|
|
|
|
|
|
Summary of Contents for Advanced SerialRAID Adapters SA33-3285-02
Page 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 2: ......
Page 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 16: ...xiv User s Guide and Maintenance Information ...
Page 18: ...xvi User s Guide and Maintenance Information ...
Page 21: ...Part 1 User Information 1 ...
Page 22: ...2 User s Guide and Maintenance Information ...
Page 48: ...28 User s Guide and Maintenance Information ...
Page 64: ...44 User s Guide and Maintenance Information ...
Page 76: ...56 User s Guide and Maintenance Information ...
Page 212: ...192 User s Guide and Maintenance Information ...
Page 228: ...208 User s Guide and Maintenance Information ...
Page 230: ...210 User s Guide and Maintenance Information ...
Page 254: ...234 User s Guide and Maintenance Information ...
Page 274: ...254 User s Guide and Maintenance Information ...
Page 330: ...310 User s Guide and Maintenance Information ...
Page 331: ...Part 2 Maintenance Information 311 ...
Page 332: ...312 User s Guide and Maintenance Information ...
Page 338: ...318 User s Guide and Maintenance Information ...
Page 430: ...410 User s Guide and Maintenance Information ...
Page 503: ...Part 3 Appendixes 483 ...
Page 504: ...484 User s Guide and Maintenance Information ...
Page 508: ...488 User s Guide and Maintenance Information ...
Page 529: ......
Page 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Page 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...