SRN
Problem
Possible Causes
49500
Description: No hot spare disk drives are available for an array that is
configured for hot spare disk drives.
Action: Determine whether any disk drives have failed or have been
rejected. To do this action:
1. Display the use of the disk drives that are attached to the SSA
adapter that logged the error (see “Changing or Showing the Use of
an SSA Disk Drive” on page 144).
2. Run diagnostics in Problem Determination mode to all pdisks that
are attached to the adapter that logged this error.
3. If any disk drives have failed, first exchange those disk drives for
new disk drives, and assign them to the use that has been specified
by the user. If the problem remains, continue with the next step.
4. Type
smitty ssaraid
and press Enter.
5. Select List Status of Hot-Spare Protection for an SSA RAID
Array.
6. Select the adapter that logged the error.
7. Observe the displayed list. Note which SSA loop contains any array
member disk drives that are listed with a protected state of no.
Devices that are in pool_A0 are connected to loop A. Devices that
are in pool_B are connected to loop B.
8. If the status field for the unprotected array member disk drive is
too_large, the hot spare disk drive is not large enough to support
that array component. Otherwise, no hot spare disk drive exists on
the loop that you noted earlier.
9. Return to the SSA RAID Arrays menu and select Change/Show Use
of an SSA Physical Disk.
10. Select the adapter that logged the error.
11. Find an appropriate disk drive, and change its use to hot spare (see
“Changing or Showing the Use of an SSA Disk Drive” on page 144).
A RAID array is configured to
use hot spare disk drives, but
no disk drive can be found that
is configured as a hot spare.
This error code is used only
when no hot spare pools have
been assigned. All arrays and
hot spare disk drives are in the
default pool0.
430
User’s Guide and Maintenance Information
Summary of Contents for Advanced SerialRAID Adapters SA33-3285-02
Page 1: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 2: ......
Page 3: ...Advanced SerialRAID Adapters User s Guide and Maintenance Information SA33 3285 02 ...
Page 16: ...xiv User s Guide and Maintenance Information ...
Page 18: ...xvi User s Guide and Maintenance Information ...
Page 21: ...Part 1 User Information 1 ...
Page 22: ...2 User s Guide and Maintenance Information ...
Page 48: ...28 User s Guide and Maintenance Information ...
Page 64: ...44 User s Guide and Maintenance Information ...
Page 76: ...56 User s Guide and Maintenance Information ...
Page 212: ...192 User s Guide and Maintenance Information ...
Page 228: ...208 User s Guide and Maintenance Information ...
Page 230: ...210 User s Guide and Maintenance Information ...
Page 254: ...234 User s Guide and Maintenance Information ...
Page 274: ...254 User s Guide and Maintenance Information ...
Page 330: ...310 User s Guide and Maintenance Information ...
Page 331: ...Part 2 Maintenance Information 311 ...
Page 332: ...312 User s Guide and Maintenance Information ...
Page 338: ...318 User s Guide and Maintenance Information ...
Page 430: ...410 User s Guide and Maintenance Information ...
Page 503: ...Part 3 Appendixes 483 ...
Page 504: ...484 User s Guide and Maintenance Information ...
Page 508: ...488 User s Guide and Maintenance Information ...
Page 529: ......
Page 530: ...Part Number 27H0678 Printed in the U S A SA33 3285 02 1P P N 27H0678 ...
Page 531: ...Spine information Advanced SerialRAID Adapters User s Guide and Maintenance Information ...