To remove a drive in bay C:
1. Locate the drive-release tab on the diskette drive.
2. Press the tab against the drive and hold it there while
pulling the drive out.
3. Disconnect the diskette drive cable and power cable
from the drive.
4. If you want to install or remove any other options, do
so now. Otherwise, go to “Completing the
installation” on page 77.
To install a drive in bay C:
1. If you have not done so, remove the server cover and
front bezel. See “Option installation” on page 125.
2. Using the instructions that come with the drive,
together with these instructions, check that any
switches or jumpers on the drive are set correctly.
Change the settings if necessary. For information
about termination requirements, see “Termination
requirements” on page 67.
3. Insert the drive into the bay.
a. Position the drive so that the connectors face the
rear of the server and the diskette eject button is
toward the outside of the server.
b. Connect the diskette drive cable and power
cable to the drive.
Note
If you have difficulty connecting a cable, turn
the cable connector over and try again;
cable connectors are keyed to connect only
one way.
Netfinity 5000 - Type 8659
71
Summary of Contents for 86594RY - Netfinity 5000 - 4RY
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...