Error Code/Symptom
FRU/Action
289
(DIMM has been disabled
by the user or system)
1. Run
Configuration/Setup,
if disabled by user
2. Ensure if a DIMM was
added/changed that
the power was
disconnected.
3. Disable DIMM, if not
disabled by user.
301
(Keyboard or keyboard
controller error)
1. Keyboard
2. System Board
303
(Keyboard controller error)
1. Keyboard
2. System Board
602
(Invalid diskette boot record)
1. Diskette
2. Cable
3. Diskette Drive
604
(Diskette drive error)
1. Run
Configuration/Setup
and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
605
(Unlock failure)
1. Diskette Drive
2. Drive Cable
3. System Board
662
(Diskette drive configuration
error)
1. Run
Configuration/Setup
and Diagnostics
2. Diskette Drive
3. Drive Cable
4. System Board
762
(Coprocessor configuration
error)
1. Run
Configuration/Setup
2. Battery
3. Processor
962
(Parallel port error)
1. Disconnect external
cable on parallel port.
2. Run
Configuration/Setup
3. System Board
11XX
(System board serial port 1
or 2 error)
1. Disconnect external
cable on serial port.
2. Run
Configuration/Setup
3. System Board
162
Netfinity Server HMM
Summary of Contents for 86594RY - Netfinity 5000 - 4RY
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...