(CONTINUED)
Notes
1. For systems that are part of a shared DASD
cluster, run one test at a time in looped mode.
Do not run all tests in looped mode, as this could
enable the DASD diagnostic tests.
2. If multiple error codes are displayed, diagnose
the first error code displayed.
3. If the computer hangs with a POST error, go to
the “Symptom-to-FRU index” on page 152.
4. If the computer hangs and no error is displayed,
go to “Undetermined problems” on page 165.
5. Power Supply problems, see “No beep
symptoms” on page 155.
6. Safety information, see “Safety information” on
page 176.
7. For intermittent problems, check the error log;
see, “Error log” on page 31.
001
IS THE SYSTEM PART OF A CLUSTER?
Yes No
002
Go to Step 004.
003
Schedule maintenance with the customer. Shut down all
systems related to the cluster. Run storage test.
004
– Power-off the computer and all external devices.
– Check all cables and power cords.
– Set all display controls to the middle position.
– Power-on all external devices.
– Power-on the computer.
– Check the error log, see “Error log” on page 31. If an
error was recorded by the system, see
“Symptom-to-FRU index” on page 152.
– Start the Diagnostic Programs. See “Running
Diagnostic test programs” on page 12.
– Check for the following responses:
1. No beep.
2. Readable instructions or the Main Menu.
DID YOU RECEIVE THE CORRECT RESPONSES?
Yes No
005
Find the failure symptom in “Symptom-to-FRU index”
on page 152.
6
Netfinity Server HMM
Summary of Contents for 86594RY - Netfinity 5000 - 4RY
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...