Ethernet controller messages
The integrated Ethernet controller might display messages
from the following device drivers:
Novell NetWare or IntraNetWare Server ODI
NDIS Adapter for level 2.01 (OS/2)
NDIS Adapter for level 4.0 (Windows NT)
SCO UNIX LLI
Novell NetWare or IntraNetWare Server ODI
driver messages:
The following error messages are
for the Novell NetWare or IntraNetWare server ODI driver.
The explanation and recommended action are included
with each message.
PCNTNW-NW-026 The MSM is unable to parse a required custom
keyword.
Explanation: The user entered an incorrect parameter keyword.
Action: Reload the driver using the correct keyword.
PCNTNW-NW-054 The adapter did not respond to the initialization
command.
Explanation: The adapter did not respond when the driver tried to initialize it.
Action: Verify that the PCI Ethernet device type is set to the default
(enabled) setting in the Configuration/Setup utility programs (see “PCI bus
control” on page 30). If the Ethernet adapter is enabled, go to “Diagnostic test
programs” on page 10 to run the diagnostic utility.
PCNTNW-NW-058 The adapter did not respond to the initialization
command.
Explanation: The interrupt request (IRQ) setting might not be valid or the
EEPROM information might be incorrect.
Action: Make sure the IRQ settings are correct in the Configuration/Setup
utility programs. See “PCI bus control” on page 30 for information on setting
the interrupt requests. If the IRQ settings are correct, replace the system
board.
PCNTNW-NW-066 The cable might be disconnected from the adapter.
Explanation: The cable might be disconnected from the server Ethernet port.
Action: Verify that a cable is connected to the Ethernet port.
PCNTNW-NW-071 The matching virtual adapter could not be found.
Explanation: You tried to load another instance of the driver with a different
I/O address. This new adapter could not be found.
Action: If you installed an Ethernet adapter, such as an IBM Netfinity 10/100
Fault Tolerant Adapter, as part of Ethernet redundancy (failover), make sure
that the adapter is seated correctly. If the adapter is seated correctly, replace
the adapter.
PCNTNW-NW-072 A resource tag is unavailable.
Explanation: The driver tried to allocate some resources that were not
available.
Action: Add or free some memory in the server. Then, restart the server.
PCNTNW-NW-073 Unable to allocate memory.
Explanation: The driver failed to allocate the memory needed for normal
operation.
Action: Add more memory, or free some memory resources in the server.
Then, restart the server.
34
Netfinity Server HMM
Summary of Contents for 86594RY - Netfinity 5000 - 4RY
Page 2: ......
Page 8: ...vi Netfinity Server HMM...
Page 12: ...Keyboards 172 Power cords 174 4 Netfinity Server HMM...
Page 195: ...Related service information 187...
Page 196: ...188 Netfinity Server HMM...
Page 197: ...Related service information 189...
Page 198: ...190 Netfinity Server HMM...
Page 208: ...200 Netfinity Server HMM...
Page 209: ...Related service information 201...
Page 219: ......
Page 220: ...IBM Part Number 10K2657 Printed in U S A S1 L 9837 4...