lead of the cable goes into the insulator hole that has a dot next to it.
Insulator
9.
Insert the assembly into the connector body, and align the polarizing slot in
the insulator with the polarizing pin inside the plug body. Tighten the clamp
nut with a 5.7 to 6.8 newton-m (50 to 60 in. lb) torque. (Do not allow the cable
and plug body to twist as you tighten the clamp nut.)
Protective
Sleeve
Plug Body
Pin
Slot
Clamp Nut
Cable
10.
Check for shorts between the conductors and between each conductor and the
plug body. Slide the protective sleeve over the plug body.
Cable-to-Cable Adapters for Twinax Cable
Do not splice cables; use an adapter. You may use IBM part 7362230, Amphenol
part 82-5588, or an equivalent for twinax cables.
Cover this adapter and the attached cable connectors with shrink or insulated
tubing to prevent accidental grounding of the connection.
Appendix B. Cable Specifications and Assembly of Cables
351
Summary of Contents for 4247 Model 003
Page 1: ...4247 Printer Model 003 User s Guide S544 5780 01 IBM ...
Page 2: ......
Page 3: ...4247 Printer Model 003 User s Guide S544 5780 01 IBM ...
Page 46: ...36 4247 Model 003 User s Guide ...
Page 62: ...52 4247 Model 003 User s Guide ...
Page 84: ...74 4247 Model 003 User s Guide ...
Page 86: ...76 4247 Model 003 User s Guide ...
Page 126: ...116 4247 Model 003 User s Guide ...
Page 152: ...142 4247 Model 003 User s Guide ...
Page 168: ...158 4247 Model 003 User s Guide ...
Page 184: ...174 4247 Model 003 User s Guide ...
Page 186: ...176 4247 Model 003 User s Guide ...
Page 188: ...178 4247 Model 003 User s Guide ...
Page 190: ...180 4247 Model 003 User s Guide ...
Page 194: ...184 4247 Model 003 User s Guide ...
Page 331: ...9 Reload the forms Chapter 20 Problems 321 ...
Page 332: ...322 4247 Model 003 User s Guide ...
Page 351: ...that of the power cord or plug whichever is less Appendix A Printer Specifications 341 ...
Page 352: ...342 4247 Model 003 User s Guide ...
Page 391: ......