116
Hardware Maintenance Manual: xSeries 220
035-XXX-S99
(Failed
RAID test on PCI slot S. S =
number of failing PCI slot.
Check System Error Log
before replacing a FRU.)
1.
Adapter
2.
SCSI Backplane
3.
Cable
035-XXX-SNN
(Check
System Error Log before
replacing a FRU. S =
number of failing PCI slot;
NN = SCSI ID of failing fixed
disk.)
1.
Fixed Disk with SCSI ID NN on RAID adapter in PCI slot S.
035-253-S99
(RAID
adapter initialization failure)
1.
ServeRAID Adapter in slot S is not configured properly.
Obtain the basic and
extended configuration status and refer to the ServeRAID Hardware Maintenance
Manual for more information.
2.
Cable
3.
Adapter
075-XXX-000
(Failed
Power Supply test)
1.
Power Supply
089-XXX-001
(Failed
Microprocessor test)
1.
Microprocessor
089-XXX-002
(Failed Optional
Microprocessor test)
1.
Optional Microprocessor 2
180-XXX-003
(Failed
System Board LED test)
1.
System Board
201-XXX-0NN
(Failed
Memory test, see "Memory
Settings" on page 32.) NN =
DIMM location.
1.
DIMM Location J1-J4
2.
Memory card
201-XXX-999
(Multiple
DIMM failure, see error text.)
1.
See error text for failing DIMMs
202-XXX-001
(Failed
System Cache test)
1.
Microprocessor CPU 1
202-XXX-002
(Failed
System Cache test)
1.
Microprocessor CPU 2
206-XXX-000
(Failed
Diskette Drive test)
1.
Cable
2.
Diskette Drive
3.
System Board
215-XXX-000
(Failed
IDE CD-ROM test)
1.
CD-ROM Drive Cables
2.
CD-ROM Drive
3.
System Board
217-XXX-000
(Failed
BIOS Fixed Disk test)
Note:
If RAID is
configured, the fixed
disk number refers to
the RAID logical
array.
1.
Fixed Disk 1
Error Code/Symptom
FRU/Action
Summary of Contents for 220
Page 1: ...IBM Hardware Maintenance Manual xSeries 220...
Page 2: ......
Page 3: ...IBM Hardware Maintenance Manual xSeries 220...
Page 18: ...10 Hardware Maintenance Manual xSeries 220...
Page 48: ...40 Hardware Maintenance Manual xSeries 220...
Page 60: ...52 Hardware Maintenance Manual xSeries 220...
Page 83: ...Installing options 75 5 If you have other options to install or remove do so now...
Page 116: ...108 Hardware Maintenance Manual xSeries 220...
Page 132: ...126 Hardware Maintenance Manual xSeries 220...
Page 138: ...132 Hardware Maintenance Manual xSeries 220...
Page 149: ...Related service information 143...
Page 150: ...144 Hardware Maintenance Manual xSeries 220...
Page 151: ...Related service information 145...
Page 152: ...146 Hardware Maintenance Manual xSeries 220...
Page 153: ...Related service information 147...
Page 154: ...148 Hardware Maintenance Manual xSeries 220...
Page 155: ...Related service information 149...
Page 156: ...150 Hardware Maintenance Manual xSeries 220...
Page 166: ...160 Hardware Maintenance Manual xSeries 220...
Page 167: ...Related service information 161...
Page 168: ...162 Hardware Maintenance Manual xSeries 220...
Page 172: ...166 Hardware Maintenance Manual xSeries 220...
Page 176: ...170 Hardware Maintenance Manual xSeries 220...
Page 177: ......