2. Installation
26
2.3 How to Install
This chapter explains how to install the actuator on your mechanical system.
2.3.1 Installation Orientation
Follow the information below when installing the actuator, as a rule.
Do pay attention to these items (except with custom-order models).
{
: Possible
ڹ
: Possible for stroke 1,000mm or less
u
: Not possible
Type
Horizontal
Installation
Vertical
Installation
Horizontally
Oriented Wall
Mount Installation
Ceiling Mount
Installation
BA4/BA4U
BA6/BA6U
BA7/BA7U
{
u
ڹ
(Note 1)
ڹ
(Note 1)
Note 1 Optional
Installation Orientation
Horizontal
Vertical
Horizontally Oriented
Wall Mount
Ceiling Mount
Caution: 1. Do not attempt to install the standard horizontal orientation type or ceiling mount
type in horizontally oriented wall mount.
Also, do not attempt to install the horizontally oriented wall mount type in standard
horizontal orientation or ceiling mount.
Doing so may cause an operational error.
2. Do not attempt to have the unit tilted or installed in vertical orientation. It may
cause an operational error.
3. Although it is available to install in horizontally oriented wall mount or ceiling
mount, it is necessary to conduct daily inspection. Installation in horizontally
oriented wall mount or ceiling mount may cause looseness on the stainless steel
sheet. Continuing to use in such a condition may cause breakage of the stainless
steel sheet. Have daily inspection, and adjust the stainless steel sheet attachment
in case of any looseness found on it. [Refer to 4.7 Procedures for Replacement
and Adjustment of Stainless Steel Sheet ]