1. Specifications Check
19
1.2.5 Allowable Moment for Actuator
Allowable Static Load
Moment [N•m]
Allowable Dynamic Load
Moment [N•m]
Type
Ma
Mb
Mc
Ma
Mb
Mc
Allowable Overhang Load
Length [L]
BA4
BA4U
16
16
31.2
6.14
6.14
11.9
Ma direction: 120mm
Mb, Mc direction: 120mm
BA6
BA6U
44.5
44.5
89.2
15.7
15.7
31.6
Ma direction: 150mm
Mb, Mc direction: 150mm
BA7
BA7U
80.7
80.7
175
33.2
33.2
72.3
Madirection: 180mm
Mb, Mcdirection: 180mm
Ma and Mb Direction Moment Offset Datum Position
BA4/BA4U
BA6/BA6U
BA7/BA7U
Moment direction
Overhang load length
Mb
Ma
Mc
L
L
29.7
36
41.5