2. Installation
31
[3] Installation Surface
x
Make sure the platform to install the actuator possesses a structure with sufficient stiffness, so
vibration would not be generated.
x
The surface where the actuator will be mounted should be a machined surface or that with an
accuracy equivalent to it, and the flatness should be 0.05mm or below.
x
Have enough space for the maintenance work.
x
The side and bottom surfaces of the base on the actuator work as the datum surfaces for the side of
the slider.
x
Use these surfaces as the datum surfaces for mounting.
䢢
Follow the diagram below when installing the device using the reference surface.
䢢
䢢
䢢
䢢
Type
A Dimensions [mm]
BA4/BA4U
3 to 5.5 or less
BA6/BA6U
BA7/BA7U
3 to 6 or less
R0.3 or less
Datum surface effective area
Datum surface
Datum
surface