10-2
10. Life
For "Standard load coefficient fws", "Load coefficient fw" and "Mounting coefficient f
α
",
refer to the contents below for configuration and selection.
[Standard load coefficient fws]
For ELECYLINDERs described in this manual, calculate with fws = 1.2.
[Load coefficient fw]
This coefficient allows consideration of the effects on life due to operating conditions.
Load
coefficient fw
Operating conditions
Guideline for
acceleration/deceleration
1.0 to 1.5
Low vibration/impact, slow operation
1.0G or less
[Mounting coefficient f
α
]
This coefficient allows consideration of the effects on life due to ELECYLINDER
mounting status.
Mounting
coefficient f
α
1.0 1.2 1.5
Mounting
status
Fixed on entire
surface
Fixed at both ends
Fixed locally
●
The actuator used in the explanatory figures above is not the ELECYLINDER.
Replace with ELECYLINDER and select the mounting coefficient.
●
Even when seated over the total length of the product, select 1.2 or 1.5 for
the mounting coefficient depending on the position of screw fixing and not
"fixing over the entire surface".
●
Various mounting methods are available for the ELECYLINDER.
"Fixing over the entire surface" is considered to be the case only when fixing
with the T-slot and square nut provided on the mounting surface.
10.1 Concept of life for slider type
Summary of Contents for EC-RR6*AH series
Page 9: ......
Page 28: ...Intro 19...
Page 130: ...1 100 1 Specifications...
Page 202: ...2 70 2 Installation...
Page 218: ...3 15 3 Wiring...
Page 240: ...4 21 4 Operation...
Page 328: ...9 15 9 External Dimensions...
Page 336: ...11 3 11 Warranty...
Page 337: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 7 ELECYLINDER Chapter12...
Page 346: ......
Page 347: ......