2.5 Installation of rod type
2-21
2. Installatio
n
2.5 Installation of rod type
Installation surface
●
The mounting frame should have a structure rigid enough to prevent the generation
of vibrationc.
●
Also consider the necessary space for maintenance work such as ELECYLINDER
replacement and inspection.
●
The body mounting surface should be a machined surface or a plane with similar
accuracy, with flatness within 0.05mm/m.
Fixing bolt
●
The bolts for fixing foot brackets and flanges on the installation surface are to be
prepared by the customer.
●
The use of high-strength bolts of ISO-10.9 or higher is recommended.
●
Make sure the internal thread and bolt effective engagement length is
approximately 1.8 times the nominal diameter or more.
●
When the tightening torque is not specified, tighten with the recommended
values in the table below.
Type Fixing
bolt
For iron
installation surface
For aluminum
installation surface
EC-R6
M6
12.34N
・
m
5.36N
・
m
EC-R7
M8
29.90N
・
m
11.48N
・
m