7-17
7.
T
roubl
es
hoot
ing
Warning: Maintenance warning 3
This is an alert that the target value of the "overload warning level" set by the customer has
been reached.
No.
Content
Causes and countermeasures
1
Before the ELECYLINDER stops operation due to the
"overload alarm", follow the troubleshooting procedure and
conduct visual inspection and maintenance.
* To disable this warning, change the "overload warning
level" in "Maintenance Information" to 100%.
[Causes]
The warning may be caused by the depletion of grease on
the ball screw/guide inside the ELECYLINDER, intrusion of
foreign matter, brake failure, motor failure, contact with
peripheral equipment, etc.
[Countermeasure 1]
Visually check for the depletion of grease on the ball
screw/guide inside the ELECYLINDER, intrusion of foreign
matter, etc.
If this is the case, clean the inside of the ELECYLINDER
and replenish the grease.
For details, refer to "8.4 Cleaning" and "8.5 Greasing
method".
[Countermeasure 2]
Check the sliding movement of the ELECYLINDER body.
If there is no abnormality in the sliding motion, there is a
possibility of motor or brake failure.
Contacting the manufacturer and replacing the motor is
recommended.
Customers may not replace the motor by themselves.
Contact IAI.
* For setting, refer to "5.2 Maintenance information" and "5.3 Setting maintenance information".
7.4 Troubleshooting by alarm groups
Summary of Contents for EC ELECYLINDER EC-GD4
Page 28: ...Intro 21 ...
Page 32: ...1 3 1 Specifications Product list Rod type Table type 1 1 Checking the product ...
Page 60: ...1 31 1 Specifications ...
Page 126: ...4 21 4 Operation ...
Page 148: ...6 15 6 Parameters ...
Page 198: ...11 3 11 Warranty ...
Page 199: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 206: ......
Page 207: ......