1-23
1. Specifications
[Pressing Force and Current Limit Value]
Caution
The relation of the current limit and the pressing force is a guideline at speed of
20mm/s.
There is some variance in the actual pressing force. The variance increases when the
current value is low.
The current limit value cannot be set outside the 20 to 40% range.
When the approach speed up to the pressing start position is 20mm/s or less, pressing
operation will take place at approach speed. When the pressing speed is 5mm/s or
more and less than 20mm/s, it may not satisfy the pressing force shown in the graph
(reference). Confirm in advance that there is no problem in the pressing force.
Also when the pressing speed is less than 5mm/s, the pressing force and the operation
may get unstable. Make sure that the speed is set at 5mm/s or more.
1.2 Mechanical specifications
Pressing Force [
N
]
Current Limit Value [%]
Lead 2
Lead 4
Lead 6