4-6
4.
O
perat
ion
Operating conditions (AVD) setting/adjustment
Setting item
Unit
Explanation
A: Acceleration
%
or
G
Set the acceleration between 1 and 100%.
Touch the [Switch units] button to switch the units to G,
allowing entries to be made in increments of 0.01G.
V: Velocity
%
or
mm/s
Set the speed between 1 and 100%.
Touch the [Switch units] button to switch the units to mm/s,
allowing entries to be made in increments of 0.01mm/s.
D: Deceleration
%
or
G
Set the deceleration between 1 and 100%.
Touch the [Switch units] button to switch the units to G,
allowing entries to be made in increments of 0.01G.
The acceleration/deceleration unit of [G] is described below.
1G = 9,800mm/s
2
: Acceleration possible up to 9,800mm/s per second.
For 0.3G, the acceleration per second is 9,800mm/s
2
x 0.3 = 2,940mm/s
2
.
The procedure on the following page can be used to configure/adjust the operating conditions
(AVD).
Note that the ELECYLINDER has an automatic calculation function for [Maximum velocity
and maximum acceleration/deceleration].
Configure/adjust the operating conditions after setting the [Installation orientation] and
[Transport load] parameters.
A
:Acceleration
V
:Velocity
D
:Deceleration
加速度
速度
減速度
AVD
4.3 Setting/adjustment of operating conditions (AVD)
Reference
Speed
Time
9800mm/s
1
s
1G
2940mm/s
0
.3G
A
: Acceleration
V
: Velocity
D
: Deceleration
Summary of Contents for EC ELECYLINDER EC-GD4
Page 28: ...Intro 21 ...
Page 32: ...1 3 1 Specifications Product list Rod type Table type 1 1 Checking the product ...
Page 60: ...1 31 1 Specifications ...
Page 126: ...4 21 4 Operation ...
Page 148: ...6 15 6 Parameters ...
Page 198: ...11 3 11 Warranty ...
Page 199: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 206: ......
Page 207: ......