7-5
7.
T
roubl
es
hoot
ing
[When an alarm is generated]
The alarm groups and warnings are as follows.
For details and countermeasures, see "7.4 Troubleshooting by alarm groups".
Alarm
group
Content
Main content and typical countermeasures
A
Overload alarm
[Content]
[Countermeasure]
Moving parts stopped abnormally.
Make sure that there are no
obstructions or obstacles.
B
Motor
error alarm
[Content]
[Countermeasure]
Motor abnormality occurred.
Contact the manufacturer and replace
the motor.
C
Controller
error alarm
[Content]
[Countermeasure]
Controller abnormality occurred.
Replace the controller cover assembly.
D
Controller-
encoder
abnormality
alarm
[Content]
[Countermeasure]
An abnormality occurred between the
controller and encoder.
Turn the power off and then on again.
If the unit still does not recover, contact
the manufacturer and replace the
controller cover assembly or motor.
E
Power supply
voltage/Power
supply capacity
error alarm
[Content]
[Countermeasure]
Controller abnormality occurred.
Check the power supply voltage for any
abnormality.
Alarm
level
Content
Main content and typical countermeasures
Warning
Maintenance
warning
[Content]
[Countermeasure]
The "maintenance period" has come to
an end.
Perform maintenance for the unit.
7.2 Troubleshooting diagnosis
Summary of Contents for EC ELECYLINDER EC-GD4
Page 28: ...Intro 21 ...
Page 32: ...1 3 1 Specifications Product list Rod type Table type 1 1 Checking the product ...
Page 60: ...1 31 1 Specifications ...
Page 126: ...4 21 4 Operation ...
Page 148: ...6 15 6 Parameters ...
Page 198: ...11 3 11 Warranty ...
Page 199: ...Appendix 12 1 Index 12 1 12 2 Revision history 12 5 ELECYLINDER Chapter12 ...
Page 206: ......
Page 207: ......