6-10
6.
P
aram
et
er
s
Parameter No.4: Home position adjustment
No. Category
Name
Symbol
Unit
Input range Default setting
at shipping
4
B
Home position
adjustment
OFST
mm
0 to 9999.99
According to
ELECYLINDER
specifications
●
Sets the distance between the home side mechanical stopper and the home position.
●
The minimum setting unit is 0.01mm.
●
Adjustment with this parameter is possible in the following situations.
(1) To match the ELECYLINDER home position and the mechanical home position after assembly
into equipment.
(2) To adjust the new home position upon reversing the default home return direction after purchase.
(3) To eliminate a slight deviation from the previous home position generated after replacing the
ELECYLINDER.
If [Parameter No.4] is [0.30mm],
the relationship between mechanical stopper and home position is as follows.
Configuration example
0.30mm
0.30mm
30.00mm
(Stroke to be used)
Parameter No.4: 0.30mm
Home position
6.4 Parameter function descriptions