3.8 Configure the alarm settings [Alarm]
The settings relating to alarm actions, alarm image, the VMD area settings, and the alarm occurrence
notification can be configured on the “Alarm” page.
The “Alarm” page has the [Alarm] tab, the [VMD area] tab, the [SCD area] tab, and the [Notification] tab.
3.8.1 Configure the settings relating to the alarm action [Alarm]
Click the [Alarm] tab on the “Alarm” page. (
®
“3.2.1 How to display the setup menu”, “3.2.2 How to operate
the setup menu”)
The settings relating to the alarm can be configured in this section. Refer to “3.8.2 Configure the settings
relating to the camera action on alarm occurrence [Alarm]” for further information about the settings relating
to the alarm images.
Alarm
[VMD alarm]
When clicking “VMD >>”, the [VMD area] tab of the “Alarm” page will be displayed. (
®
[SCD alarm]
When clicking “SCD”, the [SCD area] tab of the “Alarm” page will be displayed. (
®
[Audio detection alarm]
When clicking “Audio detection”, the [Audio detection] tab of the “Alarm” page will be displayed.
[Command alarm]
Select “On” or “Off” to determine whether or not to receive the command alarm.
The command alarm is the function that provides notification of a TCP alarm notification from the other
cameras. When “On” is selected, alarm actions will be performed between multiple cameras.
•
Default:
Off
[Reception port]
Select a port number to be used to receive the command alarm.
•
Available range:
1-65535
•
Default:
8181
The following port numbers are unavailable since they are already in use.
20, 21, 22, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 554, 995, 10669, 10670, 59000-61000
[Alarm deactivation time]
Configure the duration that detections won't be made after an alarm is detected. For example, by using this
function you can prevent E-mail from being sent too often when E-mail notifications are configured to be sent
to a mobile terminal or tablet device when an alarm is detected.
5-600s
•
Default:
5s
Note
•
The duration that alarm detections are not made can be managed for each type of alarm. For example,
even during the time when alarm detection for command alarm is not being performed, VMD alarms
and SCD alarms will be detected.
Operating Instructions
107
3 Detailed Settings