6.2.1.4 Light D3 (Operating Mode)
Possible Settings: - On
- Off
On
At this setting, the control continuously powers the cabin light.
The letter
L
appears in the display and
l
changes to
L
on the 4th line.
Off
At this setting, the cabin light remains off.
6.2.1.5 Supply Fan D4 (Operating Mode)
Possible Settings: - Automatic
- On (Continuous Operation)
- Off
Automatic
At this setting, fan operation is a function of the temperature in the
steam bath. The control switches the supply fan off when the desired
temperature plus hysteresis is reached, and switches it on again when
the temperature falls below the set value.
Also see Parameters “Steam Bath °C Set Value“ (G2) and “Hysteresis
fan“ (G3).
On (Continuous Operation)
When in continuous operation, the fan runs independently of the tem-
perature in the steam bath. In this setting, you use the control switch to
simultaneously switch the fan and the steam generator on and off.
Off
The supply fan is deactivated on this setting.
6.2.1.6 Limitation of operating time D5
Possible settings: 0-255 hours
Factory setting: 0 (=off)
With this parameter you determine if and when the steam generator
should stop operation after the safety interlock has been closed. If the
steam generator stops the message „Safety stop” is displayed. By
opening and closing the safety interlock the steam generator restarts
operation for the programmed hours.