6.2 Explanation of Parameters
Parameters D1, D2, D3 and G2 may also be modified in User Mode;
but the new settings will be lost when the unit is switched off.
6.2.1 Steam Bath Functions
6.2.1.1 Steam Bath Mode D0 (Operating Mode)
Possible Settings: -with status
-without status
The DS-Control is designed for use with steam baths. Additional infor-
mation (operational conditions) regarding steam generation may be
useful for maintenance and initial start-up. If the operational mode is
set to “with status”, an operational condition is displayed in the 1st line
of the display (also see illustration in Section “Operational Conditions
(Dependent on Unit Type)” and readout values are displayed in the
2nd and 3rd lines of the display (also see illustration in Section “Read-
out Values” ).
H11
Counter
Partial Blow-down
0 - 999 kg
Parameter Setting/
Blow-Down Parameters
010
H12
Time
Partial Blow-down
0-255 [s]
Parameter Setting/
Blow-Down Parameters
010
P1
Output limitation
25% - 100%
Parameter Setting/
Control Parameters
none
P2
Maintenance interval
0,1 - 25,5 [10³ kg]
Parameter Setting/
Maintenance Parameters
010
P3
Reset maintenance
interval
Yes / No
Parameter Setting/Mainte-
nance Parameters
010
P5
Address
1 - 999
Parameter Setting/ Data
Parameters
none
P6
Operation timer
dddd:hh
Parameter Setting/ Data
Parameters
none
P11
reset main contactor
interval
Yes / No
Parameter Settings/Main-
tenance Parameters
010
T0
Timer mode
(only with Comfort Plus)
Switch On and Switch Off
Times
(weekly, daily, off)
Parameter Setting/
Time Clock
010
U5
Pumping without K1
Yes (Main Contactor=off)
No (Main Contactor=on)
Parameter Setting/
Blow-Down Parameters
010
U6
Operating mode
1-step
internal PI-Controller
Parameter Setting/
Control Parameters
010
* Only when an internal PI-Controller is activated.
Para-
meter
Designation
Possible Settings
in Menu / Submenu
Access
Code
Please note