Product Information 3
6
ST16135-00C
3.4
Technical Data
Model Number
HV11
HV15
HV18
HV22
HV11RS
HV15RS
HV22RS
PERFORMANCE
F.A.D. litres/sec (cfm) @ 8 bar
29 (61)
38 (81)
49 (104)
60 (127)
F.A.D. litres/sec (cfm) @ 10 bar
25 (52)
33 (71)
42 (90)
52 (110)
F.A.D. litres/sec (cfm) @ 6 bar
31 (66)
41 (87)
65 (137)
Noise Level - dBA
69
70
70
71
69
70
71
Power - kW (hp)
11 (15)
15 (20)
18 (25)
22 (30)
11 (15)
15 (20)
22 (30)
Starter Type
Automatic DOL & SD
Inverter Soft Start
Drive Type
Direct
Operating Controls
Continuous Run, Automatic Stop/Start,
Reduced Energy Vent System
Variable
Rotation Speed - rev/min 50Hz (60 Hz)
1450 (1760)
870-1650
870-1650
Ambient Temperature Range °C
0 to 45
0 to 40
Maximum Relative Humidity %
85 non-condensing
Air Discharge Temp - °C (above ambient)
<8
<10
<8
<10
FACTORY SETTINGS
Minimum Pressure Valve - bar
5.5 to 6.0
Minimum Air Line Pressure - bar
(PL)
7.5 or 9.5
8.0
Maximum Air Line Pressure - bar
(PU)
8.5 or 10.5
8.5
REVS Delay Period (secs)
(Rt)
60 (8 bar) 90 (10bar)
60
Run-on-Time to Stop (secs)
(St)
10
Pressure Display Units
(PD)
0 (bar) (1 = psi, 2 = kpa)
Temperature Display Units
(Td)
0 = °C (1 = °F)
Servo Valve - bar
9.0 or 11.0
9.0
Vacuum Relief Valve
One turn anti-clockwise
INSTALLATION
Air Outlet Size - Rp
3/4
1
1
3/4
1
Minimum Room Volume - m
3
25
35
35
25
35
Air Inlet/Outlet Area - m
2
0.5
Ventilation Rate - m
3
/h
3400
Cooling Air Flow m
3
/h (cfm)
3100 (1825)
4500 (2649)
3100 (1825)
4500
(2649)
Recommended Air Receiver Capacity - L
272
COMPRESSOR OIL
Approved compressor oil
Fluid Force Red 2000 & HPO
Oil Capacity - litres
7.0
7.5
7.0
7.5
ELECTRICAL
Starter reference 400V 50 Hz SD
34994
34998
-
Circuit diagram 400V 50Hz
76849
76856
-
Starter reference 230-575V 60 Hz DOL
34995
34999
-
Circuit diagram 230-575V 60Hz
76850
76857
-
Starter reference 400/460V 50/60 Hz RS
-
34966
35000
Circuit diagram 400/460V 50/60 Hz RS
-
76851
76858
Starter reference 200V 50/60 Hz RS
-
-
34997
35001
Circuit diagram 200V 50/60 Hz RS
-
-
76852
76859