ST16135-00C
15
7
Operating Instructions
7
Operating Instructions
7.1
Operating Instructions
WARNING !
READ HEALTH AND SAFETY PRECAUTIONS
BEFORE YOU START ANY SERVICE WORK.
THE COMPRESSOR SHOULD ONLY BE
OPERATED BY AUTHORISED PERSONS FULLY
TRAINED IN THE STARTING, STOPPING AND
EMERGENCY STOP PROCEDURES.
7.1.1
Checking Procedure Before Starting
(a)
Check sight glass is full.
(b)
Check filler, drain/oil level plugs are fitted securely.
(c)
Check for any signs of oil leaks.
(d)
Check air-outlet valve is open.
(e)
Check that the emergency stop button is released.
(f)
Turn mains electricity supply on.
7.1.2
Operating Mode
When electricity is first switched on the electronic controller
(Fig 7.2) displays all symbols and illuminates both green and red
LED indicators for three seconds (Fig. 7.1)
Fig. 7.1 - Controller Display
The display then shows the software version code for a further
three seconds before showing the normal operating display
For single speed compressors the controller allows two operating
modes, automatic stop/start or continuous run.
7.1.3
Compressor Operation
Automatic stop/start is set as default. For continuous running
select Mo – MAN, using the touch sensitive symbol buttons on the
controller panel.
Select Mo using plus up/minus down buttons, press the enter
button, AUT will flash, press plus up/minus down button to
change, press enter button to select.
The operating mode may be altered when the compressor is
running or stopped.
Fig. 7.2 - Controller