61/98
Last change 10/2018 E-P | Subject to technical modifications
14. Parameter settings HYDROION
®
VAS
– CS
Regeneration cycles and times
Type HYDROION
®
VAS
25 -
CS
50 -
CS
75 -
CS
125 -
CS
150 -
CS
200 -
CS
250 -
CS
375 -
CS
600 -
CS
Connections
1"
1"
1"
1 1/2"
1 1/2" 1 1/2"
2"
(DN50)
2"
(DN50)
2"
(DN80)
Resin volume
litres
25
50
75
125
150
200
250
375
600
Injector
blue orange orange yellow yellow green
2C
2D
2F
DLFC
Type
3/4"
3/4"
3/4"
3/4"
1"
1"
1"
1"
1"
ltr./min
8.3
12.1
15.9
20.0
34.0
37.8
37.8
49.2
75.5
BLFC
ltr./min.
1.9
1.9
1.9
1.9
1.9
1.9
10.2
15.9
20.0
Full salting
– Type A
Salt consumption
kg
5
10
15
25
30
40
50
75
120
Brine volume
litres
16
32
48
81
97
129
161
242
387
Float assembly height
mm
190
300
275
315
360
340
380
455
530
Sieve bottom height
mm
130
220
200
240
285
260
290
385
460
Cycle options
– Type A
Backwash
min.
5
6
7
9
7
8
10
11
12
Brine und Slow Rinse
min.
37
40
61
49
59
61
70
65
66
Fast Rinse
min.
6
8
9
13
9
11
13
15
16
Fill
min.
9
18
27
45
53
71
17
20
31
Chlorinator (Type A)
–
Alarm delay 300 seconds
Salting
min.
12
15
23
16
19
18
20
19
20
On delay
sec.
25
25
25
25
25
25
25
25
25
Period
min.
11
14
22
15
18
17
19
18
19
Chlorinator current rating
mA
100
100
100
150
150
150
200
200
200
Economic salting
– Type B
Salt consumption
kg
2
4
6
10
12
16
20
30
48
Brine volume
litre
6
13
19
32
39
52
65
97
155
Float assembly height
mm
120
170
215
220
245
235
335
345
370
Sieve bottom height
mm
70
100
130
150
175
165
250
255
280
Cycle options
– Type B
Backwash
min.
5
6
7
9
7
8
10
11
12
Brine und Slow Rinse
min.
30
31
47
40
48
49
58
53
54
Fast Rinse
min.
6
8
9
13
9
11
13
15
16
Fill
min.
4
7
11
18
21
29
7
8
13
Chlorinator (Type B)
–
Alarm delay 120 seconds
Salting
min.
5
6
9
6
8
7
8
8
8
On delay
sec.
25
25
25
25
25
25
25
25
25
Period
min.
4
5
8
5
7
6
7
7
7
Chlorinator current rating
mA
150
150
150
200
200
200
250
250
250
Water-refresh applies to Type A and Type B
Water volume (in Stand-by)
litres
40
80
120
160
260
260
330
480
680
Interval rinsing flow
l/min
8.3
12.1
15.9
20
34
37.8
37.8
49-2
75.7