Chlorinator (Option)
Chlorinator used for the automatic disinfection
during regeneration phase of softener, consisting of:
- electrodes installed in PVC assembly element
- control cable for the connection to the micro
processor control
Control voltage:
max. 15 V
Connection:
3/8“ (VAS – CS 1)
1/2“ (VAS – CS 1,5/ 2)
The electrodes are activated automatically once the
brine intake cycle of the regeneration phase starts.
Chlorine is produced that starts the disinfection of
the resin bed.
The process is finished automatically once the
programmed time period for disinfection is elapsed.
The electrodes are de-activated again.
Measuring kit permanent hardness
The below measuring kits shall be available for
setting and control of the system:
Determination of permanent hardness:
Measuring range up to 760 ppm
Control cable
T-fitting
Chlorinator