background image

www.waterco.com

WARNING

!

HYDROCHLOR ST

mineral chlorinator

Owners Manual

This equipment must be installed and serviced by a qualified technician. 
Improper installation can create electrical hazards which could result in 
property damage, serious injury or death. Improper installation will void the 
warranty.

Summary of Contents for HYDROCHLOR ST

Page 1: ...rinator Owners Manual This equipment must be installed and serviced by a qualified technician Improper installation can create electrical hazards which could result in property damage serious injury or death Improper installation will void the warranty ...

Page 2: ...ck up 02 INSTALLATION 02 PLUMBING DIAGRAM 03 Installing the Control Unit 03 Installing Connecting Electrolytic Cell 04 OPERATION 04 Setting the time 04 CHLORINE PRODUCTION LEVELS 05 ALARMS 06 WATER CHEMISTRY 06 Salt Level 06 Water Chemistry 07 SALT CELL CLEANING PROCEDURE 07 TROUBLESHOOTING 07 TECHNICAL SPECIFICATIONS 08 GENERAL SAFETY RULES 09 WARRANTY 09 ...

Page 3: ...ol that prevents algae and bacteria from growing The chlorine then turns back into salt and the system continues as long as the generator is functioning properly Consistently maintained sanitizer levels in the pool water will prevent the growth of all common algae and bacteria A salt water chlorinated pool requires much less attention than a chlorine pool HYDROCHLOR ST Hydrochlor consists of a Con...

Page 4: ...node The reversing of polarity or electrical potential difference will then start to remove any calcium build up which may have been deposited onto the cathode This continuous reversing of polarity will keep the cell clean from calcium deposits during its operation providing the chemical balance and flow of the pool water thru the cell is maintained within normal parameters It is recommended that ...

Page 5: ... e g acid and chlorine Also ensure the Control Unit can be connected to the mains power outlet of the pool area Note that this outlet must meet the current applicable local standards at the time of installation The PUMP socket outlet in the base of the Control Unit is dedicated to the filtration pump only Do not use a double adaptor to connect another pump as this will overload the system and void...

Page 6: ...use arcing which may damage the entire system NOTE Connect all plumbing to the Cell Housing taking care that all joints are glued or tightened securely to prevent leaking Allow 24 hours for glue solvent to set before starting the Hydrochlor ST OPERATION Setting the time To set current time rotate minute hand until arrow head aligns with correct time The clock operates in a 24 hour time sequence Se...

Page 7: ...nt seasonal requirements in order to maintain satisfactory chlorine sanitizer levels The amount of chlorine produced can be adjusted by pressing the CHLORINE PRODUCTION key Press button to raise production If production already set at maximum it will turn to zero and each press will raise production by one LED till MAX If the pool water is over chlorinated simply reduce the chlorine production set...

Page 8: ... longevity of the cell and void its warranty Max Chlorine Production Level LED Amber Salt level is too high The control unit will stop the chlorine production until it s reduced below the maximum recommended Consult your pool professional how to reduce the salt level No Water Flow The flow sensor is not detecting water flowing through the cell housing Control Unit will stop chlorine production and...

Page 9: ...moved pour out the Cell Wash solution into a bucket and lightly rinse off excess calcium and Cell Wash solution from the salt cell assembly with fresh water g Reconnect the salt cell onto the filter system h Set the time back to original ON or AUTO position on the power pack to reactivate the Hydrochlor Never use products that are not specifically manufactured to clean the Hydrochlor ST s salt cel...

Page 10: ...s 3000 30 100 000 72 000 Recommended Pool Sizes SYMPTOM POSSIBLE CAUSE REMEDY Not keeping time Time clock setting power outage Electrical fault Return to distributor for repair All LEDs blinking Electrical fault Return to distributor for repair No chlorine production Control unit set to pump only Press Chlorine Production button to set the desired level Timer in OFF position Set Time to ON or AUTO...

Page 11: ...ad the Service and Installation Instructions 8 The operating safety of the chlorinator is only guaranteed if the Installation and Service instructions are correctly followed 9 The limit values stated in the Technical Specifications should not be exceeded under any circumstance 10 In the event of defective operation or fault contact the manufacturer s Technical Support Department or its nearest Aut...

Page 12: ...EAS Waterco Europe Limited Sittingbourne Kent UK Tel 44 0 1795 521 733 Waterco USA Inc Augusta Georgia USA Tel 1 706 793 7291 Waterco Canada Boucherville Quebec Canada Tel 1 450 748 1421 Waterco NZ Limited Auckland New Zealand Tel 64 9 525 7570 Waterco Limited Guangzhou China Tel 86 20 3222 2180 Waterco Far East Sdn Bhd Selangor Malaysia Tel 60 3 6145 6000 PT Waterco Indonesia Jakarta Indonesia Te...

Reviews: