2) Test the cooling system (either external and internal)
(For 440, 450 Models, Admin screen to view temperature settings).
•
Start Lounge by pressing green Start button. Keep Lounge running until water temperature exceeds 88
degrees F. *Keep the massage limits between 11 (Lower) and 18 (Upper) if water is colder than 80
degrees F.
•
To view the current temperature settings, press and hold the yellow “HOLD” button on the Touchscreen
for 5 seconds, and enter “120700”. The Default Screen will open, and the temperature settings can be
found at the lower left-hand corner of the screen.
•
With the Lounge still running, once the water temperature has reached 88 degrees F or higher, reduce
the Set Temperature to 85 degrees F. The cooling system fans should engage within 45 seconds when
there is a 2-3 degree temperature differential. Hold a piece of paper up against the fans to test if they
have been activated.
o
The internal cooling system has fans under the panel at the head end of the Lounge
•
Call HydroMassage Technical Support at 727-536-5566 if cooling system is not functioning properly.