HydroMassage
®
Pre-Installation Checklist
1)
Verify HydroMassage room is ready for installation
2)
Check to ensure the following are available:
a) Distilled water
b) 220V outlet (not applicable for 100 Series)
c) 110V outlet
d) CAT5 cable (if applicable)
e) T-Max wall cut-outs (if applicable)
f) Internet connection (if applicable)
g) External cooling system mounting structure (if applicable). Check with contractor to ensure structure is
able to hold up to 300 pounds and has method of securing system in place during use, as system will
vibrate slightly.
3)
Check to ensure no shipping damage to all HydroMassage components:
a) Shipping boxes
b) Lounge panels
c) External cooling unit (if applicable)
d) External cooling unit cabinet (if applicable)
4)
Position HydroMassage unit(s) in desired location
a) If possible, Lounge should be positioned
with electrical box (mounted on frame) facing towards center
of the room for ease of access during service
b) If external cooling system will be installed on the HydroMassage room floor, ensure there is sufficient
space available for cooling unit, and allow for a minimum of 12” of space for both the intake and
exhaust vents of the cooling unit. Exhaust should not be directed towards the HydroMassage Lounge.